The smoke evacuation takes place through a chim-
ney on the upper end of the machine and is powered
by a forced suction (venture effect) that is automati-
cally activated depending on the mode of operation
of the machine.
This chimney must then be connected to the general
workshop extraction or brought outside the workshop.
In this second case, the chimney connected to the
machine must cover at least a portion in the vertical
of 1 meter before being led outside.
For an easy installation, the chimney is generally an
aluminum tube, flexible and extensible.
The fumes of solvent dispersed in that way do not
need further treatment.

7.5. POSITIONING

The COMPACT 235 must be positioned in a well-ai-
red place.
The area must be equipped with all means provided
for by the European Legislation related to the health
and safety of the workers in the workplace.
Position the machine on the floor and make sure that
there is sufficient space around the machine to carry
out normal maintenance operations or inspections.

8.1. INITIAL WASHING

1. Dismantle the gun and empty the canister into a
suitable recipient. Raise the lid of the machine.
2. Raise the lid of the tub Press the trigger of the
spray gun and use the nylon clip (No.25) to block the
trigger of the spray gun.
3. Insert the blower nozzle into the air inlet of the
spray gun as shown in the diagram.
4. Place the spray gun
and
relative
compo-
nents on the washing
spray jet system inside
the washing tub taking
care to insert the spray
gun
into
the
spray
nozzle (No.21).
II 3 GD

8. WASHING INSTRUCTIONS

7.6. PUTTING INTO USE

The operations for connecting the machine to the
pneumatic mains supply and positioning the pipes in
the various drums are described below.
1. Connect the earthing cable (No.13) provided with
the machine and marked yellow/Green on the cable
lug to a screw on the machine Hood (No.14), on the
side of the free terminal to the earth contact of
electric system.
2. Make sure that the ON/OFF switches (No.27) of
the machine are in the off position (horizontal).
3. Connect the machine air connection (No.15) to the
line of compressed air (max. 7 bar).
4. Remove the lower door of the machine.
5. Put two drums half-filled with clean solvent on the
bottom at the base unit. One of them must be placed
under the drain of the washing tank. Immerse the two
suction pipes (No.6 and No.7) equipped with their
filters in the drum placed under the drain, which will
always contain recirculation solvent.
6. Insert the two suction pipes (No.8 and No.9) for
clean solvent into the second drum which will always
contain clean solvent
7. Replace the lower front door of the machine read
this manual carefully to ensure the best performance
from your machine.
Make sure that users read, understand and comply
with all the precautions and warnings contained
herein.
It is advisable to use the automatic wash cycle with
full loads only, otherwise there is a risk that the
nozzles not occupied by the canister or spray gun
may spray solvent
directly onto the
lid
of
the
tub,
causing
leakage
of solvent.