To reduce friction losses to a minimum, inlet (suction)
line should be short and have as few elbows as
possible.
Size the inlet according to the chart below:
Ave.
Threaded
GPM
Inlet Size
7
3/4" NPT
10
3/4" NPT
20
1" NPT
30
1-1/4" NPT
50
2" NPT
An inlet strainer will prevent suspended debris from
clogging pump.
The internal running surfaces of the pump and seals
require water lubrication for good, consistent operation.
Allowing pump to run dry will severely damage
pump and seals.
Install a pressure gauge in pump inlet line. Keep at
least two pounds per square inch pressure (2 PSI) in
inlet line whenever pump is operating. If this is not
possible, consult customer service representative.
LUBRICATION
It is not necessary to lubricate pump or motor. The
motor is equipped with sealed ball bearings, lubricated
for the life of the bearing. The mechanical shaft seal in
the pump is self-lubricating and requires no adjust-
ment. Disassemble pump to replace seal (See "Main-
tenance", Pages 8 to 9).
OPERATION
If the pump is not connected to a pressurized source, it
must first be primed. Prime the pump by filling the
suction pipe and pump body with water.
NOTICE: Observe the following precautions when
operating the pump:
1. Keep the motor dry! Do not direct stream from
pump discharge onto the motor!
2.
Hazardous pressure. Do not run the
pump with discharge shutoff, as hose may burst or
pump may be damaged due to high temperatures.
Recommended
Recommended
Inlet
Discharge
Line Size
Line Size
1"
1"
1"
1"
1-1/4"
1-1/4"
1-1/2"
1-1/2"
2"
2"
3. Do not use a standard trigger gun with this pump.
Use only trigger guns with an automatic weeping
feature. These are available as accessories and are
provided with three nozzles. The smallest nozzle
restricts the flow, allowing use of a smaller water
source. The two larger nozzles are used if the water
source will supply the pump's full capacity.
4. Do not run pump dry; to do so may damage the
seal.
5. To avoid internal damage to pump, Do not operate
with water temperature above 175 degrees F.
MOTOR SWITCH SETTINGS
Dual-voltage motors without cords (motors that can
operate at either 115 or 230 volts), are set at the
factory to 230 volts. Do not change motor voltage
setting if line voltage is 230 volts, or if you have a
single voltage motor.
NOTE: Never wire a 115 volt motor to a 230 volt line.
NOTE: Wire TEFC motors according to wiring diagram
in junction box on motor. Be sure motor is connected
for correct line voltage.
NOTE: Wire 3-Phase motors according to wiring
diagram on motor. Be sure motor is connected for
correct line voltage. Check motor rotation at setup.
Remove Motor End Cover
If you have a dual-voltage motor, and will connect it to
115 volts, follow the procedure below.
You will need to remove the motor end cover to
change the voltage setting.
End Cover Screws
Motor
End Cover
Figure 5 – Removing end cover.