Wiring Connections - STA-RITE 7SB50 Instrucciones De Operación Y Instalación

Publicidad

Idiomas disponibles

Idiomas disponibles

Your motor terminal board (located under the motor
end cover) should look like the one below.
Dial Type Voltage Selector
To change to 115 volts:
1. Make sure power is off.
2. Turn the dial counter-clockwise until 115 shows in
the dial window.
Ground
Screw
Voltage
Change Dial
Figure 6 – Voltage adjustment dial.
3. Attach the power lead wires to the power lead
terminals. Make sure the wires are secure.
4. Attach the ground wire to the green ground screw
5. Reinstall the Motor end cover
Go to Wiring Connections below.
ELECTRICAL
Ground motor before connecting to electrical
power supply.
Failure to ground motor can cause severe or
fatal electrical shock hazard.
Explosion hazard. Do not ground to a gas
supply line.
To avoid dangerous or fatal electrical shock,
turn OFF power to motor before working on
electrical connections.
Supply voltage must be within ±10% of
nameplate voltage. Incorrect voltage can
cause fire or serious damage to motor and voids
warranty. If in doubt consult a licensed electrician.
Use wire size specified in Wiring Chart (Table II,
Page 7). If possible, connect pump to a separate
branch circuit with no other appliances on it.
Wire motor according to diagram on motor
nameplate. If nameplate diagram differs from
diagrams above, follow nameplate diagram.
For All 3-phase and TEFC Motors: Follow
the wiring diagram on the motor junction box
or on the motor nameplate.

WIRING CONNECTIONS

1. Install, ground, wire and maintain this pump in
compliance with the National Electrical Code (NEC)
or the Canadian Electrical Code (CEC) and with all
local codes and ordinances that apply. Consult your
local building inspector for local information.
2. Make sure that the voltage, frequency and phase
Power Lead
(single phase or three phase) of the power supply
Terminals
agree with that stamped on the motor nameplate. If
in doubt, check with the power company.
3. Some models are equipped with three phase
motors. Three phase motors require magnetic
starters and can run in either direction, depending
on how they are connected to the power supply.
NOTICE: Dual voltage motors without cords are factory
wired for 230 volts. If necessary, reconnect the motor
for 115 volts, as shown. All cord connected motors are
wired for 115 volts (See Page 5). Do not alter the
wiring in single voltage motors.
Install, ground, wire, and maintain your pump in
comliance with the National Electrical Code (NEC) or
the Canadian Electrical Code (CEC), as applicable,
and with all local codes and ordinances that apply.
Consult your local building inspector for code
information.
NOTICE: Clamp the power cable to prevent strain on
the terminal screws.
NOTICE: Do not change motor wiring if line voltage
is 230 volts. Connect power supply as shown for
your supply voltage.
NOTICE: Some models are equipped with three phase
motors. Three phase motors require magnetic starters
and can run in either direction, depending on how they
are connected to the power supply.
6