If the chain/belt is tensioned excessively, the motor will
undergo excessive stress with a consequent increase in
current absorption.
3.3_ FIXING THE GEARMOTOR TO THE GUIDE
1_
Join the gearmotor with the head of the guide, then secure by
means of the 4 screws supplied as shown in figure 26.
2_
The motor can be rotated to three different positions, as shown
in figure 5.
3.4_ FIXING THE GEARMOTOR TO THE CEILING
1
_
In observance of positions A and B in figure 5, trace the two fixing
points of the rear guide bracket at the centre of the door. De-
pending on the type of material, the front bracket can be secure
by means of stud bolts, plugs or screws.
2_
After drilling holes at the envisaged points, leaving the gearmotor
on the ground, lift the guide from the front section and secure it
with two screws, plugs or stud bolts depending on the mounting
surface.
3_
Lift the sliding guide so that the rear attachment reaches the
same level as the front attachment, or to the same angle as the
horizontal track of the door (A fig. 27).
4_
Measure the distance between the ceiling and interaxis of the
gear unit fixing holes (B fig. 27).
5_
Bend the brackets supplied to the set measurement (measure
from the centre of the first slot on the bracket).
6_
Fit the brackets on the gear unit and reposition the sliding guide
(fig. 28).
7_
Mark the rear attachment fixing points on the ceiling (taking care
to protect the sliding guide).
Complete guide installation.
8_
Three-sections track: repeat points 3_ to 7_ for the fixing at guide
center
9_
For heavy doors or doors not running smoothly, the optional P-
100BINSUPP accessory allows a second ceiling fixing point (fig. 3).
10_
Assemble the door fixing bracket as shown in fig. 29.
11_
With the door closed, pull the cord to release the carriage as
shown in figure 30.
12_
Slide the carriage until the leaf attachment bracket is on the up-
per edge of the door, exactly perpendicular to the guide. Then fix
the leaf attachment bracket with stud bolts or screws as shown
in figure 31. Use stud bolts or screws suited to the material of the
leaf, checking that it is suitable to withstand all the force required
to open and close the door.
13_
Loosen the screws of the mechanical stops, then move it in front
of the carriage, as shown on figure 32. Firmly push the carriage in
the closing direction and, once reached the position, tighten the
screws (A) fully down.
14_
For opening phase, use any available mechanical stop, both the
door one and the complete automation track are equally fine.
15_
Attempt to move the door manually. Ensure that the carriage
slides freely, without friction on the guide, and that manual ma-
noeuvres are smooth without requiring particular effort.
3.5_ INSTALLATION OF VARIOUS DEVICES
To install the other devices envisaged, refer to the
relevant instructions. Check in figure 2 the devices that can be con-
nected to TSKY-B.
3.6_ OPTIONAL ACCESSORIES
The range of TSKY-B motors can be completed with the following op-
tional accessories:
P-100BANT adaptor for up-and-over doors;
P-150SETSKY external manual release for application on handle;
P-750BATTSKY Battery Pack;
P-100BINSUPP Additional Ceiling Fixing Kit;
P-100PROC Extension for TSKY-B;
P-100PROB Extension for TSKY-B;
• 100BANT (fig. 33)
Adaptor for up-and-over doors
100BANT must be used to power operate counterweight up-and-over
doors with drive models TSKY-B and TSKY1-B.
• 150SETSKY
External release (see relative instructions).
• 750BATTSKY
Battery pack (see relative instructions).
• 100BINSUPP (fig. 3)
Additional Ceiling Fixing Kit.
• 100PROC (fig. 8 - 13)
Extension for TSKY-B with chain.
• 100PROB (fig. 16 - 25)
Extension for TSKY-B with belt.
3.7_ ELECTRICAL CONNECTIONS
All electrical connections must be made withthe system
disconnected from the power supply.
1_
To open the protection cover and access the electronic control
unit of TSKY-B, press on the side of the cover and turn the panel
door as shown in fig. 34.
2_
Route the connection cables to the various devices through the
cable clamps, leaving a length 20÷30cm more than necessary.
See para. 2.2 for the type of cables and figure 3 for connections.
3_
Make the connections as shown in the diagram in figure 35. Ter-
minals are removable to facilitate connections.
3.8_ CONNECTING TO THE POWER SUPPLY
For electric power supply of TSKY-B simply connect the 230 Vac line to
the transformer safety fuse holder (A fig. 35).
TSKY-B must be connected to the power mains by skilled
and qualified personnel, in possession of all requirements
for full compliance with all legal provisions, standards and
regulations.
The electric power line must be protectedagainst short
circuits and dispersion to earth; a device must be fitted to
enable shutoff of the power supply during installation or
maintenance of TSKY-B.
4. K995MA-S ELECTRONIC BOARD (fig. 35)
4.1. CONTROL BOARD FOR SECTIONAL DOORS
MICROPROCESSOR-CONTROLLED LOGIC
INPUT STATUS LED'S
LINE INPUT FUSE
BUILT-IN FLASHING LIGHT CIRCUIT
433.92 MHz BUILT-IN RADIO RECEIVER
ENCODER SENSOR FOR OBSTACLE DETECTION AND SELF-LEARN-
ING OF TRAVEL
DIAGNOSTICS OF MALFUNCTIONS SIGNALLED BY LED
COMPATIBILITY WITH OUR APPS: TAUOPEN AND TAUAPP
ATTENTION:
-
do not use single cables (with one single wire), ex. telephone
cables, in order to avoid breakdowns of the line and false con-
tacts;
-
do not re-use old pre-existing cables;

4.2. TECHNICAL CHARACTERISTICS

Board power supply
Max motor 1 power DC
Fast acting fuse for protection of input power supply
13.5V AC (F1 - 5x20)
Fast acting fuse for protection of auxiliary circuits
18V DC (F2 - 5x20)
Motor power supply circuits voltage
BUS circuit voltage for auxiliary devices
Logic circuits supply voltages
Operating temperature
3. TERMINAL BOARD CONNECTIONS
4.
Terminals
Function
Description
TRANSFORMER
L1 - L2
Power input 230 Vac
POWER SUPPLY
24 Vac board power supply input – Powered
by transformer in relative compartment of
BOARD POWER
FS1 - FS2
SUPPLY
TSKY-B motor and protected by fuse (F 6,3A)
on the 230 Vac power line.
22
24 V AC - 50 Hz
8 A - 30 V DC
F 16 A
F 3,15 A
30 V DC
30 V DC
5V DC
-20 °C ÷ +55 °C