The installer must first check suitability of the existing structure, to
ensure that:
-
it is possible to attach the track of T-SKY on the upper part of
the up-and-over door support frame or on the lintel immediately
above (if flush with the frame), see detail A of fig. 34;
-
the distance between the sliding track of T-SKY and highest
point reached by the up-and-over door during rotation (dis-
tance X of fig. 36) is at least 1 cm more than the thickness of
the door.
To ensure correct installation, proceed as follows:
-
position 150BAN on the centreline of the door, perfectly perpen-
dicular and flush with the upper limit of the up-and-over door (B
fig. 35) and secure by means of 4/6 self-drilling screws;
-
assemble 150BAN as shown in details C and E of fig. 35, re-
membering to remove the curved section of the rod;
-
fix 150BAN to the slide, observing the distance of 1 cm from the
rail (D fig. 34) and sliding the perforated rod to align with the
fixing holes (E fig. 35);
• 150SE
External release (see relative instructions)
• 750KITSCB24
Battery kit with charge control card (see relative instructions)
3.7_ Electrical connections
All electrical connections must be made withthe sy-
stem disconnected from the power supply.
1_
To open the protection cover and access the electronic con-
trol unit of T-SKY, press on the side of the cover and turn the
panel door as shown in fig. 37.
2_
Route the connection cables to the various devices through
the cable clamps, leaving a length 20÷30cm more than nec-
essary. See para. 2.2 for the type of cables and figure 3 for
connections.
3_
Make the connections as shown in the diagram in figure 38.
Terminals are removable to facilitate connections.
3.8_ Connecting to the power supply
For electric power supply of T-SKY simply connect the 230 Vac line
to the transformer safety fuse holder (A fig. 38).
T-SKY must be connected to the power mains by skil-
led and qualified personnel, in possession of all requi-
rements for full compliance with all legal provisions,
standards and regulations.
The electric power line must be protectedagainst short
circuits and dispersion to earth; a device must be fitted
to enable shutoff of the power supply during installa-
tion or maintenance of T-SKY.
4_
K690M ELECTRONIC BOARD

4.1_ Technical specifications

Board power supply
Max. DC motor power
Quick-acting motor protection fuse
(F1 - 5x20)
Quick-acting battery protection fuse
(F2 - 5x20)
Quick-acting 24 Vdc auxiliary circuit protection
fuse (F3 - 5x20)
Motor power circuit supply voltage
Auxiliary device circuit power supply voltage
Logic circuit power supply voltage
Operating temperature
Housing protection rating
16
All manuals and user guides at all-guides.com
4.2_ Diagnostics leds
DL1 (OPEN/CLOSE)
DL2 (STOP)
DL4 (PHOTO)
DL3 (ERR)
DL5 (POWER)
4.3_ Terminal board connections
FS1 - FS2
1-4
N.B.
2-4
3-4
5-6
6-7
8-9
10-11 (Antenna) AERIAL input for built-in RX 433,92 MHz. 10=
M4
17 - 18
24 Vac - 50 Hz
50 W - 24 Vdc
4.4_ Memorisation procedure
F 10 A
IMPORTANT: After powering up the control panel, wait for 2
seconds before starting the adjustment procedures.
F 10 A
On completion of automation installation:
1_ bring the door to approx. 1 m from the closing stop;
F 2 A
2_ position dipswitch no. 10 to ON;
3_ activate the automation via one of the following inputs: O/C,
24 Vdc
24 Vdc
4_ the door should start to close.
5 Vdc
N.B.: if the door opens, suspend programming and reset the
-20 °C ÷ +70 °C
IP 30
T-SKY Series
red led indicating use of OPEN/CLOSE
button
green led indicating use of STOP but-
ton
green led indicating PHOTOCELL
red led indicating ERRORS
green led indicating POWER ON (also
when battery powered)
24 Vac board power supply input – Powered by
transformer in relative compartment of T-SKY motor
and protected by fuse on the 230 Vac power line.
(Photocell) PHOTOCELL OR SAFETY DEVICE input ac-
tive on closure (Normally Closed contact); when activated,
during the closing phase, generates a door stop command
followed by complete door re-opening; in the opening phase
generates a temporary stop command until the detected
obstacle is removed (only if dip switch nr. 3 is set to ON). In
the case of multiple safety devices, connect all NC contacts
IN SERIES. 1= PHOTOCELL .
The photocell transmitter must always be powered by
terminals 5 and 6, as the safety system check is per-
formed on the latter (Fototest).
To disable the safety system test function, or when
using the photocells, set dipswitch 6 to OFF. If the fo-
totest function fails, there is a control unit fault.
(Stop) STOP button input (Normally Closed contact); stops
the door at any point of travel, temporarily inhibiting auto-
matic closure, if programmed. It resumes operation when
the OPEN/CLOSE button is pressed or radio control is
used. 2= STOP, 4= COMMON
(Open/Close) OPEN/CLOSE button input (Normally Open
contact); activates door opening and closing and is con-
trolled by operation of dipswitches 2 and 4. 3= OPEN/
CLOSE.
(Photocell TX) 24 Vdc output, for PHOTOCELL TX POW-
ER SUPPLY (only those that perform the Fototest function)
max. nr. 1 photocell transmitter.
5= NEGATIVE, 6= POSITIVE.
(Photocell RX) 24 Vdc output, max. 15 W, for POWER
SUPPLY OF RX AND POSSIBLE OTHER TX ELEMENTS
OF PHOTOCELLS, EXTERNAL RECEIVERS etc; connect
max. 3 pairs of photocells. 6= POSITIVE, 7= NEGATIVE.
(Flashing light) 24 Vdc FLASHING LIGHT output (max. 15
W). The signal supplied is already specially modulated for
direct use. The flashing frequency doubles during the clos-
ing phase. 8= POSITIVE, 9= NEGATIVE.
EARTH, 11= SIGNAL.
quick connector for ENCODER and MOTOR connec-
tion. Brown = 5 Vdc (+5V), green = ENCODER SIGNAL
(ENC), White = 0 Vdc (GND), black = MOTOR NEGA-
TIVE, red = MOTOR POSITIVE.
24V – 1.2Ah BATTERY input.
radio control or board button (O/C).
electrical panel (disconnect the panel from the power
supply for at least 5 sec. and return dipswitch no. 10 to
OFF), and while disconnected, invert the motor supply
wires. Then resume the procedure from point 1.