Pump Reassembly; Restart Instructions; Priming The Pump - Pentair SUPERFLO Manual De Instalación Y Guía Del Usuario

Bomba de alto rendimiento
Ocultar thumbs Ver también para SUPERFLO:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

6
DO NOT run the pump dry. If the pump is run dry, the mechanical seal will be damaged and the pump will start leaking. If this
occurs, the damaged seal must be replaced. ALWAYS maintain proper water level. If the water level falls below the suction port,
the pump will draw air through the suction port, losing the prime and causing the pump to run dry, resulting in a damaged seal.
Continued operation in this manner could cause a loss of pressure, resulting in damage to the pump case, impeller and seal and
may cause property damage and personal injury.

Pump Reassembly

1. When installing the replacement seal into the seal
plate, use soapy water to wet the rubber boot before
pressing it into the seal plate.
2. Remount the seal plate to the motor.
3. Before installing the rotating portion of the seal on
the motor shaft, wet the motor shaft with soapy water
and slide the seal onto the motor shaft. Ensure that
the carbon face contacts the ceramic face of the
stationary seat. Press the seal into the seal plate
with your thumbs and wipe off the ceramic with a
clean cloth.
4. Grease the motor shaft thread and screw impeller
onto the motor shaft.
5. Screw in the impeller lock screw (counter-clockwise
to tighten).
6. Remount the diffuser onto the seal plate. Make
sure the plastic pins and holding screw inserts are
aligned.
7. Grease the diffuser quad ring and seal plate O-ring
prior to reassembly.
8. Grease the bolt threads, assemble the motor sub-
assembly to the strainer pot-pump body by using
the two through bolts for proper alignment. Do not
tighten the through bolts until all 4 bolts are in place
and finger tightened.
9. Fill the pump with water.
10. Reinstall the pump lid and plastic clamp;
see the next section, 'Restart Instructions'.
11. Reprime the system.
QUAD
RING
SUPERFLO
High Performance Pump Installation and User's Guide
®
SEAL PLATE
IMPELLER
LOCKING
SCREW
DIFFUSER
IMPELLER
SCREW
Motor Assembly

Restart Instructions

If pump is installed below the water level of the pool,
close return and suction lines prior to opening hair and
lint pot on pump. Make sure to re-open valves prior to
operating.

Priming the Pump

The pump strainer pot must be filled with water before
the pump is initially started.
Follow these steps to prime the pump:
1. Remove the pump lid plastic clamp. Remove the
pump lid.
2. Fill the pump strainer pot with water.
3. Reassemble the pump cover and plastic clamp onto
the strainer pot. The pump is now ready to prime.
4. Open the air release valve on the filter, and stand
clear of the filter.
5. Turn on the switch or time clock.
6. When water comes out of the air release valve,
close the valve. The system should now be free of
air and recirculating water to and from the pool.
7. For 2-speed pumps:
Pump should run on high-speed for priming.
The pump should not run longer than 8 minutes
before priming is achieved.
BOLT
MOTOR SLINGER
MOTOR SHAFT
SEAL PLATE O-RING

Publicidad

Capítulos

Tabla de contenido

Solución de problemas

loading

Tabla de contenido