SAFETY INFORMATION
Carefully read and follow all safety instructions in this
manual or on pump.
This is the safety alert symbol. When you see this
symbol on your pump or in this manual, look for one of
the following signal words and be alert to the potential for
personal injury!
warns about hazards that will cause serious
personal injury, death or major property damage if ignored.
warns about hazards that can cause serious
personal injury, death or major property damage if ignored.
warns about hazards that will or can cause
minor personal injury or property damage if ignored.
The word NOTICE indicates special instructions which are
important but not related to hazards.
Electrically powered sump pumps normally give many years
of trouble-free service when correctly installed, maintained,
and used. However, unusual circumstances (interruption
of power to the pump, dirt/debris in the sump, flooding that
exceeds the pump's capacity, electrical or mechanical failure
in the pump, etc.) may prevent your pump from functioning
normally. To prevent possible water damage due to flooding,
consult your dealer about installing a secondary sump
pump, a DC backup sump pump, and/or a high water alarm.
See "Troubleshooting" in this manual for information about
common sump pump problems and remedies.
California Proposition 65 Warning
This product and related accessories contain
chemicals known to the State of California to cause cancer,
birth defects or other reproductive harm.
MOTOR, SWITCh, & CORd SPECIFICATIONS
Model Number
Motor hP
SP3318T
1/3
SP3318V
1/3
SP33115T
1/3
SP5518T
1/2
SP5518V
1/2
SP55115T
1/2
293 WRIGHT STREET, DELAVAN, WI 53115 WWW.FEMYERS.COM
PH: 888-987-8677
© 2013 Pentair, Ltd. All Rights Reserved.
Individual Branch Circuit Required
Max. Load Amps
9.0
9.0
9.0
5.5
5.5
5.5
InstallatIon, operatIon, & parts Manual
SP33 and SP55 Series
Submersible Sump Pumps
1.
Know the pump application, limitations, and potential
hazards.
2.
Disconnect power before servicing.
3.
Release all pressure within system before servicing any
component.
4.
Drain all water from system before servicing.
5.
Secure discharge line before starting pump. An
unsecured discharge line will whip, possibly causing
personal injury and/or property damage.
6.
Check hoses for weak or worn condition before each
use, making certain that all connections are secure.
7.
Periodically inspect sump, pump and system
components. Keep free of debris and foreign objects.
Perform routine maintenance as required.
8.
Provide means of pressure relief for pumps whose
discharge line can be shut-off or obstructed.
9.
Personal Safety:
a. Wear safety glasses at all times when working with
pumps.
b. Keep work area clean, uncluttered and properly
lighted – replace all unused tools and equipment.
c. Keep visitors at a safe distance from work area.
d. Make workshop child-proof – with padlocks, master
switches, and by removing starter keys.
10. When wiring an electrically driven pump, follow all
electrical and safety codes that apply.
11. This equipment is only for use on 115 volt and is
equipped with an approved 3-conductor cord and
3-prong, grounding-type plug.
To reduce risk of electric shock, pull
plug before servicing. This pump has not been
investigated for use in swimming pool areas. Pump
is supplied with a grounding conductor and
grounding-type attachment plug. Be sure it is
connected only to a properly grounded grounding-
type receptacle.
Where a 2-prong wall receptacle is encountered, it
must be replaced with a properly grounded 3-prong
receptacle installed in accordance with codes and
ordinances that apply.
(Amps)
Cord Length
15
15
15
15
15
15
Switch Setting
inches (mm)
On
8'
13" (330)
6" (152)
8'
8-1/2" (216)
4" (102)
15'
13" (330)
6" (152)
8'
13" (330)
6" (152)
8'
8-1/2" (216)
4" (102)
15'
13" (330)
6" (152)
MY503 (09/27/13)