DR560 Changing the Heating Element
For this operation, turn off the station or disconnect the tool and wait until the tool temperature
drops to room temperature.
1. Removing
Loosen the deposit lid
(a), remove the screw (b)
and withdraw the heating
element (c).
2. Placing
b
c
Insert the new Heating
Element (a), tighten the screw
(b) and then the lid (c).
Important
!
a
Before placing, make sure to
!
insert the internal gasket into
the Glass Solder Collector.
Important
For a proper connection
it is essential to insert the
cartridge by lining it up to
the mark
.