DR560 Changing the Heating Element
To perform this operation, turn off the station or disconnect the tool.
1. Loosening
The deposit lid needs to be
loosened.
2. Removing
Loosen the screw as shown
and remove the
Heating Element.
3. Placing
Place the new Heating
Element and follow the steps
conversely.
Important
For a proper connection it is essential to insert the cartridge by lining it up to the mark
22
2
3
1
.