Values are expressed in mm
4- Secure the gearmotor to the plate, tightening the nuts. To facilitate this operation
on the gearmotor, an appropriate socket wrench is provided.
5- Prepare the operator for manual operation as described in paragraph 8.
5.4. Assembling the rack
5.4.1. Steel rack to weld (Fig. 11)
1) Fit the three threaded pawls on the rack
element, positioning them at the bottom
of the slot. In this way, the slot play will
enable any future adjustments to be
made.
2) Manually take the leaf into its closing
position.
3) Lay the first section of rack level on the
pinion and weld the threaded pawl on
the gate as shown in Fig. 13.
4) Move the gate manually, checking if
the rack is resting on the pinion, and weld
the second and third pawl.
5) Position another rack element end to end with the previous one, using a section
of rack (as shown in Fig. 14) to synchronise the teeth of the two elements.
6) Move the gate manually and weld the three threaded pawls, thus proceeding
until the gate is fully covered.
5.4.2. Steel rack to screw (Fig. 12)
1) Manually take the leaf into its closing
position.
2) Lay the first section of rack level on the
pinion and place the spacer between
the rack and the gate, positioning it at
the bottom of the slot.
3) Mark the drilling point on the gate. Drill
a Ø 6,5 mm hole and thread with an M8
male tap. Screw the bolt.
4) Move the gate manually, checking if
the rack is resting on the pinion, and
repeat the operations at point 3.
5) Position another rack element end to end with the previous one, using a section
of rack (as shown in figure 14) to synchronise the teeth of the two elements.
6) Move the gate manually and carry out the securing operations as for the first
element, thus proceeding until the gate is fully covered.
56
Notes on rack installation
• Make sure that, during the gate travel, all
the rack elements do not exit the pinion.
• Do not, on any account, weld the rack
elements either to the spacers or to each
other.
• When the rack has been installed, to ensure
it meshes correctly with the pinion, it is
advisable to lower the gearmotor position
by about 1.5 mm (Fig.15).
• Manually check if the gate correctly
reaches the mechanical limit stops
maintaining the pinion and rack coupled
and make sure there is no friction during gate
Fig.10
travel.
• Do not use grease or other lubricants
between rack and pinion.
6.1. Control board connection
Before attempting any work on the board (connections, programming,
maintenance), always turn off power.
Follow points 10, 11, 12, 13 and14 of the GENERAL SAFETY OBLIGATIONS.
Following the instructions in Fig. 3, route the cables through the raceways and make
the necessary electric connections to the selected accessories.
Always separate power cables from control and safety cables (push-button,
receiver, photocells, etc.). To avoid any electric noise whatever, use separate
sheaths.
6.1.1. Earthing
Fig.11
Connect the earth cables as shown in Fig.16 ref.A.

6.1.2. Electronic control unit

In the "C" version gearmotors, the electronic control unit is fitted to an adjustable
support (Fig. 16 ref. 1) with transparent lid (Fig. 16 ref. 3).
The board programming push buttons (Fig. 16 ref. 4) have been located on the lid.
This allow the board to be programmed without removing the lid.
For correct connection of the control unit, follow indications the specific instructions.
4
Fig.12
2
2
3
6.1.3. Connection of power cable
(for Falcon 424C only)
The FALCON 424C gearmotor houses a screw terminal with fuse-holder (Fig 17 Ref.
A) connected to the primary circuit of the toroidal transformer. The mains power
cable 230 / 115 V ~ must be connected to this terminal, respecting what was specified
in Fig. 17. If you have to replace the fuse, use a fuse type T1.6A/250V - 5x20 for a
230V power supply and type T3.15A/250V - 5x20 for a 115V power supply.
Fig.13
Fig.14
7
ENGLISH
1
6. START-UP
1
A
Fig.15
Fig.16
Fig.17