The light switch is on top of the cabinet (Rif. 6).
13.Night blind - optional - (Fig. 8 - Fig. 9)
To avoid useless leakages of cold and to guarantee the hygiene of the stock displayed during the
nightime, manual or motorised night blinds are available as optionals.
The movement of the night blind, if motorised, is adjusted during testing.
For the correct functioning of the cabinet, the lowest part of the night blind must maintain a distance of
about 10mm from the suction plate, it must neither rest on nor go past this limit.
The switch for the motorised blind is found at the side of the light switch (Fig. 6 Rif. 7).
Manual night blind assembly instructions (Fig. 8)
There are two models of night blind (Mod.1, Mod.2); the assembly, however, remains the same:
- Fix the blind supports 1 (A).
- Load the spring turning the flat pin in a clockwise direction, keeping the blind still so that the triangle
on the cap of the tube is high up (with the point down) (B).
- Insert the flat pin 7 in the blind support. If users want to use the automatic stop so that the blind stops
on each turn, the flat pin must be inserted in the position with "UP" positioned high up (B).
If the blind is assembled in a different position from this, the automatic stop is disconnected.
- Position the blind fastening 3 on the pin, insert it into the blind support and rotate it 90° (C)
Indicative table for spring unit loading
Manual blinds width
Preload recommended (with material rolled up)
Max load springs (with material completely unrolled)
CAUTION: Remove the stop-lever 9, where present, before use.
Motorised night blind assembly - canalised (Fig. 9)
1 -
Insert the right-hand 90° lock (7) rotating it until it blocks in the rectangular seat (A) made on the
support box.
2 -
Insert the left-hand canalised blind on the right-hand one using the pin (B).
3 -
Insert the left hand 90° lock in the box site rotating it until it blocks in the rectangular seat (A)
made on the support box.
14.Lamp replacement (Fig. 6 - Rif. 10)
To replace the lamp, follow the instructions below:
- Disconnect power to the cabinet;
- Turn the protective case and the lamp by approx. 90° (until it clicks) and extract them from the lamp
base by pulling them downwards;
- Remove the caps, pull out the lamp from the protective case and replace it with a new one;
- Restore the caps, making sure that the contacts are correctly housed in the relevant holes;
- Reposition the lamp assembly and the case in the lamp base and turn it by 90° until it clicks;
- Restore power supply.
15.Multiplexing of cabinets (Fig. 7 - Rif. 18)
To multiplexing two or more cabinets, follow the instructions below:
- Remove the endwalls;
- Position the cabinets side-to-side;
- Remove the back panels to gain access to the rod holes;
- Join the rods and the straps using the screws supplied;
- Mount the back panel.
MULTIPLEXING KIT
Ref.
Code
Q.ty
1
02047000
3
2
04230600
6
3
04480112
10
4
04711040
1
5
04711065
3
6
02940652
1
05060070 02 17/05/2010
Alignment pin profile D 10
Hexagonal nut M8
Ring D 8,5x24
Screw TCEI M8X35 (Cylindrical head and flush hexagon)
Screw TCEI M8X120 (Cylindrical head and flush hexagon)
Alignment pin D 4x80
< 1250 mm
>1250
20 - 30
25 - 30
50
55
Description
Berlino 3
English
33