Digital program switch menu
EN
14
HOUR RANGES
This can be used to set an opening mode for different hour
ranges every day
ENABLE
YES
NO
FROM 1 TO 6 HOUR
MONDAY
RANGES
*Important: verify that the last time slot
used terms to 23.59
TUESDAY
SEE MONDAY
WEDNESDAY
SEE MONDAY
THURSDAY
SEE MONDAY
FRIDAY
SEE MONDAY
SATURDAY
SEE MONDAY
SUNDAY
SEE MONDAY
YES
COPY
NO
SYSTEM INFO
Displays the system information
COUNTERS
CYCLES
METERS TRAVELED
RADAR ENABLING
see maintenance section
MAINTENANCE
DIAGNOSTIC
INPUTS
: Displays all the internal and external radar inputs:
V.P. and lateral guards, key, emergency and fire
alarm/antipanic button
EXITS
:Allows you to enable the following outputs :
electric locks
air blades and lamp.
ENCODER
:Also allows you to view the encoder position
: displays the last 8 errors with date and time. See error table
ERROR LIST
MODEL
SW DOOR
SW DATA
SW DS2
SW DATA
Motor.Temp
Diagnostic
EN
START TIME 00:00
END TIME 00:00
MODE
CLOSED
ENTRY ONLY
EXIT ONLY
AUTOMATIC
PARTIAL
OPEN
: can be used to copy the first timer entered
( Monday) in all the other days.
SETUP
Allows you to set/view the switch parameters
WINGS FREE
ON
NEAR
: Perform a reset
: if entered, requires the password for any functionality editing,
USER PASSWORD
if set with 0000 is not required
DATE/TIME
LAMP
MODE
HOUR RANGES
DIMMING
IB1 MODE
ENTRY ONLY
EXIT ONLY
AUTOMATIC
IB2 MODE
Same as IB1 MODE
LCD CONTRAST
LCD RETRO
PARAMETERS -
accessible only with expert password (default 2426)
Allows you to set/view the switch parameters
RESET
RUN
STATUS
MOVEMENT
OPENING SPEED
PARAMETERS
CLOSING SPEED
OPENING
ACCELLERATION
CLOSING
ACCELERATION
OPENING BRAKING
CLOSING BRAKING
SPEED OF
APPROACH
IN OPENING
SPEED OF
APPROACH
IN CLOSING
NOTES: Opening and closing speed variable from 10 to 80 m/s.
In some cases the speed setting may not be reached, depending on the
size of the opening, acceleration and braking settings and weight of the door
: allows the use of "Wings free",
if the automation board is set up
for the "Wings free", function.
SA: only fire alarm or Emergency button
SAMT: only alarm, key, or power outage
FO: hour ranges
2 hour ranges
START TIME 00:00 on
END TIME 00:00 off
: only interlocked doors
: allows you to perform a new learning cycle of the
parameters and sensors connected (in case of use
of monitored sensors)
: Is valid for sensors N.O. with test and N.C. with test and
allows you to manually enter the sensors not learned
in the learning phase
Safety door opening 1
Safety door opening 2
Same as safety door opening 1
Lateral safety 1
Same as safety door opening 1
Lateral safety 2
Same as safety door opening 1
Antipanic
Same as safety door opening 1
: set maximum speed that can be reached
in opening
: set maximum speed that can be reached
in closing
: allows you to change the acceleration of the door
during opening. Variable from 1 to 12.
: allows you to change the acceleration of the door
during closing. Variable from 1 to 12.
: allows you to change the braking of the door
during opening. Variable from 1 to 12.
: allows you to change the braking of the door
during closing. Variable from 1 to 12.
: speed at the end of the braking ramp. Variable
From 1 to 5 cm/s.
: speed at the end of the braking ramp. Variable
From 1 to 5 cm/s.
17
ON
OFF