en
24 | KTS 530 / 540 / 570 (KTS 5 Series) | Decommissioning
6.
Decommissioning
6.1

Temporary shutdown

In the event of lengthy periods of non-use:
Disconnect KTS 530 / 540 / 570 (KTS 5 Series) from
the mains.
6.2
Change of location
If the KTS 530 / 540 / 570 (KTS 5 Series) is passed on,
all the documentation included in the scope of delivery
must be handed over together with the unit.
The KTS 530 / 540 / 570 (KTS 5 Series) is only ever
to be transported in the original or equivalent pack-
aging.
Unplug the electrical connection.
Heed the notes on initial commissioning.
6.3
Disposal and scrapping
KTS 530 / 540 / 570 (KTS 5 Series), accessories and
packaging should be sorted for environmental-friendly
recycling.
Do not dispose KTS 530 / 540 / 570 (KTS 5 Series)
into household waste.
Only for EC countries:
The KTS 530 / 540 / 570 (KTS 5 Series) is
subject to the European directive 2012/19/
EC (WEEE).
Dispose of used electrical and electronic
devices, including cables, accessories and
batteries, separately from household waste.
Make use of the local return and collection
systems for disposal.
Proper disposal of
KTS 530 / 540 / 570 (KTS 5 Series) pre-
vents environmental pollution and possi-
ble health hazards.
|
1 689 979 987
2015-09-22
7.
Technical data
7.1
General data
Property
Operating voltage
Power consumption through vehicle bat-
tery or power supply
Dimensions (L x W x H)
Weight (without connecting cables)
Degree of protection
Operating temperature
Storage Temperature
Relative operating humidity
7.2
Interface protocols
The following interfaces and their associated protocols
are supported for control unit diagnosis in compliance
with ISO 15031:
R
ISO 9141-2 (communication lines K and L)
R
SAE J1850VPW and SAE J1850PWM
(communication lines BUS+ and BUS-)
R
CAN ISO 11898 ISO 15765-4 (OBD)
(communication lines CAN-H and CAN-L)
R
CAN Single Wire
R
CAN Low Speed
7.3
Multimeter specifications
Measurement channel 1 (CH1)
Measurement channel 2 (CH2)
Input resistance > 900 kohms.
7.3.1

DC measurement (CH1 and CH2)

!
Use measurement cables for measurements smaller
than 60 VDC, 30 VAC or 42 VACpeak only.
Property
Value/range
Measuring range
200 mV — 60 V
Accuracy of CH1
±0.75 % of measured value
plus ±0.25 % of measuring range
Accuracy of CH2
±2 % of measured value
plus ±0.5 % of measuring range
Resolution
100 µV — 100 mV
(depending on measuring range)
Value/Range
7 VDC — 30 VDC
approx. 6 Watt
170 x 120 x 40 mm
325 g
IP 20
5 °C – 40 °C
41 °F – 104 °F
-25 °C – 60 °C
-13 °F – 140 °F
90 % non-