7.3.2
AC and effective-value measurement
(CH1 and CH2)
i
The measuring ranges in measurement modes "U"
and "I" are given as peak-to-peak values. Conse-
quently, the digital display box is "grayed out" if the
set measuring range is briefly exceeded (overload).
Property
AC frequency range
Measuring range
AC accuracy at 100 Hz
rms accuracy at ≤ 100 H
Resolution
7.3.3
Resistance measurement (CH1)
Property
Value/range
Measuring range
100 Ω — 1 MΩ
Accuracy up to 200 KΩ
±0.75 % of measured value
plus ±0.25 % of measuring range
Accuracy up to 1 MΩ
±2 % of measured value
plus ±0.25 % of measuring range
Resolution
0.1 Ω — 1000 Ω
(depending on measuring range)
Input resistance
> 9 MΩ
7.3.4
Current measurement (CH1 and CH2)
Sensor
Shunt (CH1 only)
30 A clamp (CH1 only)
100 A clamp
600 A clamp
1000 A clamp (CH1 only)
7.3.5
Continuity tester (CH1)
Property
Value/range
Measurement current
2 mA
No-load voltage
≤ 5 V
Continuity
< 10 Ω (with audible feedback)
7.3.6
Diode measurement (CH1)
Property
Value/range
Measurement current
2 mA
No-load voltage
≤ 5 V
Maximum diode voltage
2 V
Robert Bosch GmbH
Decommissioning | KTS 530 / 540 / 570 (KTS 5 Series) | 25
Value/range
10 Hz — 400 Hz (-3 dB)
200 mV — 30 V
±2 % of measurement value, ad-
ditional
±0.5 % of measurement range
100 µV — 100 mV
(depending on measuring
range)
Measuring range
±600 mA
±30 A
±100 A
±600 A
±1000 A
7.4
Oscilloscope specifications
Property
Value/range
Measurement channel CH1 floating/non-floating
Measurement channel CH2 non-floating
Input resistance
> 900 kohms
CH1/CH2
Measuring range
0 V — 60 VDC, 30 VAC, 42 VACpeak
Coupling
DC, AC,
DC(+) (only positive range is
shown),
DC(-) (only negative range is
shown).
Signal source
U, 30 A (CH1 only), 100 A, 600 A,
1000 A (CH1 only),
Diagnosis pins 1 to 15
(not pins 4, 5)
X-deflection
50 µs — 1 s
Trigger mode
Manual, Auto-Time, Auto-Level
Trigger source
CH1, CH2
Pretrigger time
0 % — 80 %
Frequency range
> 1 MHz (typical 5 MHz)
Memory depth per channel 50 signal curves with 512
curve points
7.5
Power pack
Property
Input voltage
Input frequency
Output voltage
Operating temperature
7.6
Bluetooth Class 1
Wireless connection
KTS 540 / 570 to PC/Laptop
Workshop environment in the open
space
If the vehicle door or window is open
and the engine is still running in the ve-
hicle interior
en
Value/Range
90 VAC — 264 VAC
47 Hz — 63 Hz
15 V
0 °C — 40 °C
Minimum range
30 meters
10 meters
|
1 689 979 987
2015-09-22