Page 14
ENGLISH
5.2.2
To set the Feeder Times
Sets the amount of time the controller activates the
feeder per dose.
ORP SETUP: CL 1
FEEDER
FEED TM
DELAY OT
SET POINT
HI ALERT
LOW ALERT
WAIT PH
STOP PH
NEXT CLN JAN 01
ERO LP/MBV/
Type
Salt
ERO HP
Default
CONT
Do not use
Range No Change
Allowed
5.2.3
To set the Overfeed or Feed Delay
ORP SETUP: CL 1
FEEDER
FEED TM
DELAY OT
SET POINT
HI ALERT
LOW ALERT
WAIT PH
STOP PH
NEXT CLN JAN 01
ERO LP/MBV/
Type
Salt
ERO HP
Default OVERFEED
Do not use
OFF
Range OFF 24 HRS
OVERFEED: Salt only. Will alarm and not feed if ORP
has activated for too long, preventing damage to the
cell.
FEED DELAY: Sets the amount of time the controller
waits to dose the pool again.
C1900 ORP and pH ChemLink™ Controller
NONE
500 MS
45 MIN
200
650
100
NO
NO
Liquid
Gran
30 Sec
5 Sec
0.5 Sec to
0.5 Sec to
CONT
5 Sec
NONE
500 MS
45 MIN
200
650
100
NO
NO
Liquid
Gran
10 Min
30 Min
1-99 MIN
1-99 MIN
|
Installation & Operation Manual
5.2.4
To set the ORP Setpoint
Specifies the level of sanitizer to be maintained.
ORP SETUP: CL 1
FEEDER
FEED TM
DELAY OT
SET POINT
HI ALERT
LOW ALERT
WAIT PH
STOP PH
NEXT CLN JAN 01
Default
Range
5.2.5
To set the Alarm - High Alert
Sets an alarm to deactivate the controller in the event of
an ORP reading that is out of high range. This could be
an indication of a mechanical malfunction in the feeding
system.
ORP SETUP: CL 1
FEEDER
FEED TM
DELAY OT
SET POINT
HI ALERT
LOW ALERT
WAIT PH
STOP PH
NEXT CLN JAN 01
Default
Range
5.2.6
To set the Alarm - Low Alert
Sets an alarm to deactivate the controller in the event of
an ORP reading that is out of low range. This could be
an indication of a mechanical malfunction in the feeding
system.
ORP SETUP: CL 1
FEEDER
FEED TM
DELAY OT
SET POINT
HI ALERT
LOW ALERT
WAIT PH
STOP PH
NEXT CLN JAN 01
Default
Range
NONE
500 MS
45 MIN
200
650
100
NO
NO
650
200 to 900
NONE
500 MS
45 MIN
200
650
100
NO
NO
950
650 to 950
NONE
500 MS
45 MIN
200
650
100
NO
NO
100
100 to 640