5.3.2
To set the Feeder Times
Sets the amount of time the controller activates the
feeder per dose.
PH SETUP: CL 1
FEEDER
FEED TM
DELAY OT
SET POINT
HI ALERT
LOW ALERT
ACID/BASE
NEXT CLN JAN 01
NEXT CAL JAN 01
CAL AT PH
Type
ERO LP/MBV/ERO HP
Default
Range
5.3.3
To set the Feed Delay
Sets the amount of time the controller waits to dose the
pool again.
PH SETUP: CL 1
FEEDER
NONE
FEED TM
500 MS
DELAY OT
0 MIN
SET POINT
200
HI ALERT
650
LOW ALERT
100
ACID/BASE
NO
NEXT CLN JAN 01
NO
NEXT CAL JAN 01
CAL AT PH
Type
ERO LP/MBV/ERO HP
Default
Range
5.3.4
To set the PH Setpoint
Specifies the level of sanitizer to be maintained.
PH SETUP: CL 1
FEEDER
FEED TM
DELAY OT
SET POINT
HI ALERT
LOW ALERT
ACID/BASE
NEXT CLN JAN 01
NEXT CAL JAN 01
CAL AT PH
Default
Range
ENGLISH
C1900 ORP and pH ChemLink™ Controller
NONE
CONT
45 MIN
7.5
8.4
6.8
ACID
7.5
Do not use
NONE
CONT
45 MIN
200
8.4
6.8
ACID
7.5
Do not use
NONE
CONT
45 MIN
7.5
8.4
6.8
ACID
7.5
7.5
7.0 to 8.2
5.3.5
Sets an alarm to deactivate the controller in the event of
an PH reading that is out of high range. This could be
an indication of a mechanical malfunction in the feeding
system.
Liquid
Default
30 Sec
Range
0.5 Sec to
CONT
5.3.6
Sets an alarm to deactivate the controller in the event of
an PH reading that is out of low range. This could be an
indication of a mechanical malfunction in the feeding
system.
Default
Liquid
Range
30 Sec
0.5 Sec to
CONT
5.3.7
ACID: Feeds acid to lower the pH.
BASE: Feeds base material to raise the pH.
DEFAULT: Acid.
|
Installation & Operation Manual
To set the Alarm - High Alert
PH SETUP: CL 1
FEEDER
NONE
FEED TM
CONT
DELAY OT
45 MIN
SET POINT
7.5
HI ALERT
8.4
LOW ALERT
6.8
ACID/BASE
ACID
NEXT CLN JAN 01
NEXT CAL JAN 01
CAL AT PH
7.5
7.5 to 8.4
To set the Alarm - Low Alert
PH SETUP: CL 1
FEEDER
NONE
FEED TM
CONT
DELAY OT
45 MIN
SET POINT
7.5
HI ALERT
8.4
LOW ALERT
6.8
ACID/BASE
ACID
NEXT CLN JAN 01
NEXT CAL JAN 01
CAL AT PH
7.5
6.8 to 7.4
To set the Acid or Base Feed
PH SETUP: CL 1
FEEDER
NONE
FEED TM
CONT
DELAY OT
45 MIN
SET POINT
7.5
HI ALERT
8.4
LOW ALERT
6.8
ACID/BASE
ACID
NEXT CLN JAN 01
NEXT CAL JAN 01
CAL AT PH
7.5
8.4
6.8