C1900 ORP and pH ChemLink™ Controller
5.2.7
To set the Wait or Stop pH
ORP SETUP: CL 1
FEEDER
FEED TM
DELAY OT
SET POINT
HI ALERT
LOW ALERT
WAIT PH
STOP PH
NEXT CLN JAN 01
Wait for pH:
YES= ORP will not feed at the same time as pH.
NO= ORP will feed regardless of when pH feeds.
Default= YES
Stop for pH:
YES= ORP will not feed if the pH is out of range.
NO= ORP will feed regardless of pH.
Default=YES
5.2.8
To set the Next Cleaning
Manually set reminder to clean the ORP sensor. Enter
Month, then Year for automatic reminder. Default= JAN
01 (essentially OFF)
ORP SETUP: CL 1
FEEDER
FEED TM
DELAY OT
SET POINT
HI ALERT
LOW ALERT
WAIT PH
STOP PH
NEXT CLN JAN 01
|
NONE
500 MS
45 MIN
200
650
100
NO
NO
NONE
500 MS
45 MIN
200
650
100
NO
NO
Installation & Operation Manual
5.3 To Configure the ChemLink pH Controller
At the main ChemLink screen, use the arrow keys
to highlight PH SETUP and press SELECT. Using
the arrow keys, highlight the item to edit and press
SELECT. Use the arrow keys to scroll through the
list of options for the item. When the correct option is
selected, press SELECT to accept the entry. Pressing
BACK/DONE before pressing SELECT restores the
previous setting.
Pressing BACK/DONE before pressing SELECT also
cancels and returns to the main ChemLink screen.
CHEMLINK
SETUP
CHEMLINK 1
CHEMLINK 2
Highlight an
item and press
SELECT
PH SETUP: CL 1
FEEDER
NONE
FEED TM
CONT
DELAY OT
45 MIN
SET POINT
HI ALERT
LOW ALERT
ACID/BASE
ACID
NEXT CLN JAN 01
NEXT CAL JAN 01
CAL AT PH
5.3.1
To set the Feeder Type
PH SETUP: CL 1
FEEDER
NONE
FEED TM
CONT
DELAY OT
45 MIN
SET POINT
7.5
HI ALERT
8.4
LOW ALERT
6.8
ACID/BASE
ACID
NEXT CLN JAN 01
NEXT CAL JAN 01
CAL AT PH
7.5
ENGLISH
CHEMLINK 2
ORP 650
PH 7.5
ORP SETUP
PH SETUP
ORP MANUAL FEED
PH MANUAL FEED
LEVEL SWITCH
7.5
8.4
6.8
7.5
NONE - Default
ERO LP
Non typical
MBV
applications
ERO HP
GRAN
LIQUID - For liquid peristaltic
pumps
Page 15
SETUP
OK