Pin Signal
1
+ PULSE
2
+ DIRECT.
3
+ ENABLE
4
not connected
5
+ F/H STEP
6
− F/H STEP
7
not connected
8
+ READY
1)
Not supported by stepping motor controller SEC−ST.
2)
Connections bridged in the connecting cable
(e.g. cable type KSPC−SECST−...).
The AMPLIFIER connection has been designed for stepping
motor controllers with 5 V control signals.
Use the special cables from the Festo range for connecting
the stepping motor controller.
If you use a stepping motor controller from a different
manufacturer, you must prepare a cable in accordance
with the manufacturer's instructions. In this case, connect
the cable screening on both sides with the plug housing.
Festo SPC200−SMX−1 0309a English
SEC−ST Pin Signal
Clk + 5
9
− PULSE
Dir + 5
10
− DIRECT.
EN + 5
11
− ENABLE
12
not connected
1)
13
not connected
1)
14
not connected
15
− READY
1) 2)
SEC−ST
Clk −
Dir −
En −
1) 2)
19