All manuals and user guides at all-guides.com
ENGLISH
SYMBOLS USED ON LCD
~
AC Measurement
-
Negative DC Value
O.L.
Apo
Overload: Range Exceeded
Low Battery
HOLD
V
Voltage Measurement
Resistance in Ohms
k
3
Kilo 10
ELECTRICAL SPECIFICATIONS
DC Voltage Measurement
Range
Resolution
Accuracy
1.0V ~ 1000V
0.001V ~ 1V
± (1.0% + 4 digits)
-1.0V ~ -1000V
0.001V ~ 1V
Overload Protection:
1000V
Input Impedance (Nominal): > 10M , < 100pF
AC Voltage Measurement
Range
Resolution
Accuracy
1.2V ˜ 750V
0.001 ~ 1V
± (1.5% + 3 digits)
Overload Protection:
750V RMS
Frequency Response:
45 to 400 Hz
Response:
Averaging
Input Impedance (Nominal): > 10M , < 100pF
Input Impedance (Low Z) > 3k , < 200pF, up to 600V RMS
AC Current Measurement
Range
Resolution
Accuracy
0.9A ~ 200A
0.1A
± (2.0% + 8 digits)
Overload Protection:
Current:
200A
Frequency:
45 to 1kHz
Response:
Averaging
Resistance Measurement
Range
Resolution
Accuracy
400 ˜ 4M
0.1 ˜ 0.001M
± (1.0% + 4 digits)
40M
0.01M
± (2.0% + 4 digits)
Overload Protection:
600V RMS
Continuity Test
Overload Protection
Open Circuit Voltage
Threshold (Appx.)
< 0.44V
600V RMS
< 40
Overload Protection:
600V RMS
Non Contact Voltage Detector
On Voltage
Appx. 25V AC and above
DC Measurement
AT
Auto Range Active
Auto Power-Off Active
Hold Active
A
Current in Amps
Continuity Test
M
6
Mega 10