jbc Advanced Serie Manual Del Usuario página 4

Ocultar thumbs Ver también para Advanced Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

HANDPIECES 2010, 2210, 2045 AND 2245
The following soldering handpieces can be
connected to the AD 4200 station:
- Handpiece 2010 ref. 2010000. Power: 20W. For
high precision work, SMD etc. Available
cartridges 2010: see page 55.
- Handpiece 2210 ref. 2210000. Power: 20W. For
high precision work, SMD etc. Available
cartridges 2210: see page 55.
- Handpiece 2045 ref. 2045000. Power: 50W. For
general soldering work. Available cartridges
2045: see page 54.
- Handpiece 2245 ref. 2245000. Power: 50W. For
general soldering work. Available cartridges
2245: see page 54.
The handpieces and cartridges 2210 and 2245
comply with the MIL-SPEC-2000 referring to the
potential difference between the soldering tip and
ground connection, must be less than 2 mV.
For a soldering handpiece to work properly, the
following components are required: the control
unit, soldering iron stand, one handpiece and one
cartridge.
The soldering iron is connected to the station in the
following way:
The cable connection of the soldering iron is
connected to the plug in the soldering iron stand
AD 8200 and the cable connection of the soldering
iron stand is plugged into the terminal of the
station. Please find the connection plan on page 1.
Handpiece 2010 Ref. 2010000
Handpiece 2210 Ref. 2210000
3
OPERATION
LED lights
Red LED -ON- when lit, it indicates that the station is
plugged in the mains.
Green LED -READY- when lit, it indicates that the
system is ready and correctly set for working.
The green led light is on after a few seconds, is the
time needed to carry on the self-checking system.
The green light is pulsing when the soldering iron is
in sleep mode.
If the green led is not lit, the reason why, will be one
of the following:
1. The handpiece or the cartridge are not plugged
in.
2. The maximum available power has been
exceeded for too long - e.g. in a very thick
soldering at the high repetition rates.
3. The handpiece or cartridge has a short
circuit or an open circuit.
4. Any other trouble preventing the system from
working properly.
The green led goes off when the cartridge tip
touches the extractor and the station stops the
power supply.
The handpiece will reset itself automatically should
the cartridge short circuit or go open circuit.
Should the handpiece be subject to:
- An electrical surge or the cartridge has not been
fitted correctly.
Please turn the unit off and switch on again to
reset.
Handpiece 2045 Ref. 2045000
Handpiece 2245 Ref. 2245000
ENGLISH
Cartridges

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Advanced ad 4200

Tabla de contenido