jbc Advanced Serie Manual Del Usuario página 5

Ocultar thumbs Ver también para Advanced Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

ENGLISH
Sleep function
One of the Series Advanced features is that when
the handpiece is placed in the holder, the
temperature at the tip drops automatically to the
sleep temperature. This function is only possible
because of the quick response time which does
not make the user realise the temperature rise to
reach the selected temperature. Also by this, the
oxidation of the tinning of the tip is considerably
reduced and tip life is extended.
To indicate that the soldering iron is in sleep-mode,
the green led starts pulsing. These parameters can
be modified using the Console AC 2600 Ref. 2600000.
In order to take advantage of the above
mentioned feature and as a security measure,
it is necessary to place the handpiece on stand
when the iron is not being used.
When connecting an old version solder stand, it may
happen that the sleep function does not work.
To resolve this problem, you should make a bridge
between pins number 3 and 5 from the aerial
connector of the cable of the stand, that plugs in
the station.
Aerial connector
Bridge between
pin number 3 & 5
Fume extractor accessories
For handpieces
2045/2245
0495000
Specially designed for the Advanced Series
handpieces 2010/2210 and 2045/2245. Easily clips
onto the handpiece and can be quickly removed
for easy maintenance.
For handpieces
2010/2210
0265000
Changing the handpiece's cartridge
With the Advanced system, the cartridge can be
changed quickly, without turning off the station,
so you have two soldering irons in one. Here is
what to do to change the cartridge:
1 - Place the handpiece and remove the cartridge.
2 - Place the handpiece on top of the new cartridge,
press it slightly down and remove the handpiece.
3 - Press the cartridge into the opening A, B or C:
A. For straight cartridges 2010 and 2210.
B. For curved cartridges 2010 and 2210.
C. For cartridges 2045 and 2245.
4

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Advanced ad 4200

Tabla de contenido