Wayne T50S10-2 Manual De Instrucciones De Operación

Ocultar thumbs Ver también para T50S10-2:

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Operating Instructions and Parts Manual
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
Description
this submersible pump is designed to
supply water at the required pressure with
high efficiency and a long service life. to
maximize pump life, care must be taken in
its installation and usage.
Unpacking
after unpacking the submersible pump,
carefully inspect for any damage that
may have occurred during transit. Check
for loose, missing or damaged parts.
Safety Guidelines
this manual contains information
that is very important to know
and understand. this information
is provided for SaFety and to
PReVent eQUIPMent PRoBLeMS. to
help recognize this information, observe
the following symbols.
danger indicates an
imminently
hazardous situation which, if NoT
avoided, WIll result in death or serious
injury.
Warning indicates a
potentially
hazardous situation which, if NoT
avoided, Could result in death or serious
injury.
Caution indicates a
potentially
hazardous situation which, if NoT
avoided, MAY result in minor or moderate
injury.
Notice indicates
important
information, that if NoT followed, MAY
cause damage to equipment.
nOTe: Information that requires special
attention.
© 2011 Wayne/Scott Fetzer Company.
Deep Well
Submersible Pumps
General Safety
Information
CalIfOrnIa PrOPOSITIOn 65
including lead, known to the state of
California to cause birth defects and
other reproductive harm. Wash hands
after handling.
General SafeTy
1. Read the instruction manual
included with the product carefully.
Be thoroughly familiar with the
controls and the proper use of the
equipment.
2. Know the pump application,
limitations and potential hazards.
or explosive fluids such as gasoline,
fuel oil, kerosene, etc. do NoT use in
explosive atmospheres. Pump should
only be used with liquids compatible
with pump component materials.
Failure to follow this warning can result
in personal injury and/or property
damage.
pressure from the system before
attempting to install, service, relocate
or perform any maintenance. lock the
power disconnect in the open position.
Tag the power disconnect to prevent
unexpected application of power.
3. Personal Safety:
a. Wear safety glasses at all times
when working with pumps.
b. Keep work area clean, uncluttered
and properly lit.
c. Keep visitors at a safe distance from
work area.
REMINDER: Keep your dated proof of purchase for warranty purposes!
Attach it to this manual or file it for safekeeping.
For parts, product & service information
visit www.waynepumps.com
T50S10-2, T50S10-4, T51S10-4,
T75S10-2, T75S10-4, T100S10-2
4. Do not pump chemicals or corrosive
This product
5. When installing pump, prevent
contains chemicals,
6. always test the water from the well
7. Do not run the pump dry or
do NoT use to
licensed or certified electrician.
pump flammable
8. For maximum safety, the unit should
9. Make sure the line voltage and
10. Do not attempt repairs to the
disconnect power
and release all
11. avoid kinking electrical cord
connect the green wire (or green and
yellow wire) to a live terminal!
liquids. Pumping these liquids
shortens the life of the pumps seals
and moving parts and WIll void
warranty.
foreign matter from falling into
well, contaminating the water and
damaging internal mechanical
components.
for purity before use. Check with
local health department for test
procedure.
damage will occur and WIll void
warranty.
All wiring should
be performed by a
be connected to a grounded circuit
equipped with a ground fault circuit
interrupter (GFCI) device.
frequency of electrical current
supply agrees with the motor wiring.
electric motor. all repairs to the
motor must be completed at a
licensed or certified electrical motor
repair shop.
and protect electrical cord from
sharp objects, hot surfaces,
oil and chemicals. Replace or
repair damaged or worn cords
immediately.
Risk of electric
shock! NeveR
340601-001 5/11

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Wayne T50S10-2

  • Página 1 REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping. For parts, product & service information © 2011 Wayne/Scott Fetzer Company. 340601-001 5/11 visit www.waynepumps.com...
  • Página 2: Pre-Installation

    Deep Well Submersible Pump Operating Instructions and Parts Manual General Safety electrical System nOTe: See Installation Wiring Diagrams for typical wiring hookups and control Information (Continued) WIrInG/GrOUnDInG box identification. 12. Use wire of adequate size to fuse Size minimize voltage drop at the motor. hazardous voltage! The Volts Standard Dual elem.
  • Página 3 1 phase, 2 or 3 wire cable, 60 Hz (copper wire size—service to motor) electrical System Pump Model Control Box (Continued) Voltage Wires t50S10-2 16965-002 use only control box specified t50S10-2 none for your pump. Make sure motor and t51S10-4...
  • Página 4: Pump Installation

    Deep Well Submersible Pump Operating Instructions and Parts Manual Installation 3. With wire stripping tool, trim Consult national electrical Code, as insulation back 1/2" (12.7 mm) from well as local code, for grounding WIre SPlICInG power supply wire and motor lead information and safety guidelines.
  • Página 5 Deep Well Submersible Pump Operating Instructions and Parts Manual Installation 10. Install sanitary well seal or pitless COnneCTInG TO TanK/WaTer (Continued) SySTeM adapter unit, well unit, electrical conduit and surface piping. See Figure 9 for illustration of piping To prevent sand- Installation must meet all applicable connections to pre-charged pressure locking pump,...
  • Página 6: Troubleshooting Chart

    Deep Well Submersible Pump Operating Instructions and Parts Manual Installation (Continued) CONTROL BOX ELECTRICAL DISCONNECT (3 WIRE MODELS) VENTILATED PRESSURE GAUGE WELL CAP AIR VOLUME CONTROL PRESSURE SWITCH SUBMERSIBLE CABLE UNION PITLESS TO HOUSE ADAPTOR SERVICE CHECK VALVE GATE VALVE SEE TABLE RELIEF VALVE BLEEDER...
  • Página 7 Deep Well Submersible ump Operating Instructions and Parts Manual Troubleshooting Chart Symptom(s) Possible Cause(s) Corrective action(s) Fuses blow or overload protector 1. Low or high voltage 1. If voltage variation is greater than 10% of nameplate rating, trips while motor is running call power company to adjust voltage.
  • Página 8 Warranty For one year from the date of purchase, Wayne Water Systems (“Wayne”) will repair or replace, at its option, for the original purchaser any part or parts of Deep Well Submersible Pumps (“Product”) found upon examination by Wayne to be defective in materials or workmanship.
  • Página 9: Directives De Sécurité

    Garder tous les visiteurs à distance sans danger du secteur de travail. MÉMENTO: Gardez votre preuve datée d'achat à fin de la garantie! Joignez-la à ce manuel ou classez-la dans un dossier pour plus de sécurité. 9-fr © 2011 Wayne/Scott Fetzer Company. 340601-001 5/11...
  • Página 10: Système Électrique

    Puits profond pompes submersibles Instructions D’utilisation et Manual de Pièces Généralités Sur la excessive menant à une usure BranCHeMenTS ÉleCTrIQUeS prématurée de la pompe, (2) l'eau Sécurité (Suite) toutes les installations électriques est corrosive, (3) du gaz ou de l'air doivent être conformes aux exigences entraîné...
  • Página 11 Câble monophasé à 2 ou 3 fils, 60 Hz (taille du fil en cuivre—du tableau au moteur) Système électrique Modèle Boîte de Tension fils pompe no. contrôle no. (Suite) t50S10-2 16965-002 la terre. Le système de mise à la t50S10-2 aucune terre doit être conforme à tous les codes de l'électricité locaux et t51S10-4 aucune nationaux en vigueur.
  • Página 12: Épissure De Fil

    Puits profond pompes submersibles Instructions D’utilisation et Manual de Pièces Système électrique 5. Centrer la gaine sur le connecteur de bout, puis y appliquer de la (Suite) chaleur de manière uniforme avec Consulter les autorités compétentes un chalumeau (une allumette ou un EMBOUTIR OU SERTIR chargées d'appliquer les codes OU SOUDER...
  • Página 13: Installation De Pompe

    Puits profond pompes submersibles Instructions D’utilisation et Manual de Pièces Installation DÉMarraGe InITIal/nOUVeaUX ou à un démarreur magnétique (Suite) PUITS (voir Diagrammes de Câblage d'Installation). ne PaS encore Ne JAMAIs FAIRe Pour éviter de faire démarrer la pompe. fonctionner la tomber la pompe pompe avec la soupape de décharge 5.
  • Página 14 Puits profond pompes submersibles Instructions D’utilisation et Manual de Pièces Installation (Suite) 8. Une fois que l'eau est claire à ce stade, ouvrir entièrement la vanne BOÎTE DE CONTRÔLE à obturateur, puis faire marcher la SECTIONNEUR ÉLECTRIQUE (MODÈLES À 3 FILS) pompe jusqu'à...
  • Página 15 Puits profond pompes submersibles Instructions D’utilisation et Manual de Pièces notes 15-fr...
  • Página 16 Puits profond pompes submersibles Instructions D’utilisation et Manual de Pièces Tableau de dépannage Symptôme(s) Cause(s) Possible(s) Mesures Correctives Le moteur ne démarre pas, mais 1. aucune tension à la boîte de 1. Installer un fusible ou un fusible de type de surcharge les fusibles ne sont pas grillés contrôle ou au sectionneur approprié.
  • Página 17 Puits profond pompes submersibles Instructions D’utilisation et Manual de Pièces Tableau de dépannage Symptôme(s) Cause(s) Possible(s) Mesures Correctives très peu d'eau ou rien n'est 1. Clapet de non-retour bloqué 1. Libérer la soupape si bloquée. Inverser la position de la pompé...
  • Página 18: Garantie Limitée

    Instructions D’utilisation et Manual de Pièces Garantie limitée Pendant un an à compter de la date d’achat, Wayne Water Systems (“Wayne”) va réparer ou remplacer, à sa discrétion, pour l’acheteur original toute pièce ou pièces de Pompes submersibles pour puits profond (“Produit”) déterminées défectueuses après examen par Wayne en termes de matériaux ou de fabrication.
  • Página 19 RECORDATORIO: ¡Guarde su comprobante de compra con fecha para fines de la garantía! Adjúntela a este manual o archívela en lugar seguro. 19-Sp © 2011 Wayne/Scott Fetzer Company. 340601-001 5/11...
  • Página 20: Información General De Seguridad (Continúa)

    Bomba sumergible para pozos profundos Manual de instrucciones de operación y piezas Información general de Sistema eléctrico COneXIOneS De CaBleaDO seguridad (Continúa) todos los cableados deben cumplir CaBleaDO/COneXIón a TIerra con los requisitos del Código eléctrico 13. Las juntas de tuberías compuestas nacional, así...
  • Página 21 Monofásico, cable de 2 ó 3 alambres, 60 Hz (calibre del cable de cobre – trabajo al motor) Sistema eléctrico nº de (Continúa) modelo de n° de caja de Voltaje Cables bomba control Tamaño de fusible t50S10-2 16965-002 elem t50S10-2 nada Voltios estándar doble t51S10-4 nada t75S10-2...
  • Página 22: Instalación

    Bomba sumergible para pozos profundos Manual de instrucciones de operación y piezas encendedor no proporcionarán calor las conexiones de los tomas tirando Si la sobrecarga principal se dispara, suficiente). suavemente de ellos. busque lo siguiente: Mantenga el 7. Centre el cuerpo del aislador sobre 1.
  • Página 23: Instalación (Continúa)

    Bomba sumergible para pozos profundos Manual de instrucciones de operación y piezas Instalación procedimiento cuando encienda la (Continúa) bomba por primera vez. No encienda CABLEADO TEMPORAL PARA EL la bomba con la válvula de descarga CENTRO CENTRO DE CONTROL O LA CAJA NuNCA deje que los cables de la bomba DE CONTROL DE DESCONEXIÓN ELÉCTRICA...
  • Página 24 Bomba sumergible para pozos profundos Manual de instrucciones de operación y piezas Instalación (Continúa) COneXIón a Un SISTeMa De aGUa/ CAJA DE CONTROL PROTECCIÓN POR DESCONEXIÓN ELÉCTRICA TanQUe (MODELOS DE TRES CABLES) TAPA PARA POZO MANÓMETRO CON VENTILACIÓN CONTROL DE VOLUMEN DEL AIRE INTERRUPTOR DE PRESIÓN ¡Peligro de alta CABLE...
  • Página 25 Bomba sumergible para pozos profundos Manual de instrucciones de operación y piezas notas 25-Sp...
  • Página 26: Tabla De Identificación De Problemas

    Bomba sumergible para pozos profundos Manual de instrucciones de operación y piezas Tabla de Identificación de Problemas Síntoma(s) Causa(s) Posible(s) Medida Correctiva(s) el motor no arranca, 1. no hay voltaje en la caja de control o en el 1. Instale el fusible o fusible de tiempo de retardo correcto pero los fusibles no interruptor de desconexión están quemados...
  • Página 27 Bomba sumergible para pozos profundos Manual de instrucciones de operación y piezas Tabla de Identificación de Problemas Síntoma(s) Causa(s) Posible(s) Medida Correctiva(s) La bomba arranca con demasiada 1. Hay fugas en el sistema 1. Compruebe las conexiones del tanque con agua frecuencia jabonosa.
  • Página 28: Garantía Limitada

    ("Producto") que después de un examen Wayne encuentre que tenían defectos en su material o mano de obra. Sírvase llamar a la compañía Wayne (800-237-0987, desde eUa) para recibir instrucciones al respecto o comuníquese con el distribuidor más cercano a su domicilio.

Este manual también es adecuado para:

T50s10-4T51s10-4T75s10-2T75s10-4T100s10-2

Tabla de contenido