General Recommendations - GYS POWERDUCTION 110LG Manual De Instrucciones

Ocultar thumbs Ver también para POWERDUCTION 110LG:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 47
Translation of the original instructions
Start chronogram by PLC
Gâchette
Mecha
méca
trigger
relais
external
extérieur
relay
mode
drive mode
asservissement
Safety and fault setting of the device
- If the temperature input does not change after 5 s, the product goes into fault "E12".
-  If a thermocouple cuts out, then the regulation stops because the voltage U T° exceeds the maximum voltage of 4.9 V.
-  If the temperature drops significantly in a short period of time (when thermocouple probes are disconnected, for ex-
ample), the heating stops and the product goes into fault "E11".
-  To have the most accurate regulation possible, the measuring point(s) must be as close as possible to the inductor.
This is the reason for the 2 thermocouples on the external interface.
- The display shows the highest temperature measured by the sensors.
MAINTENANCE

General recommendations

• It is recommended to change the cooling liquid every two years, otherwise you may damage the Powerduction's lance.
Before adding the liquid, dust the product and check for leaks.
• Regularly check the tightening of the power screws and the appearance of the electrical power connections.
Recommended tightening torque for power screws
Dimensions screws
M5
Material
steel
Torque
4 Nm
• It is essential that the maintenance of the product is performed by qualified, authorised staff, that is fully aware of the
recommendations outlined in this manual.
• Never clean, lubricate or perform maintenance on the product when it's being used.
• Before any maintenance work, set the On / Off switch to « 0 » to switch off the machine, .then disconnect it it from
the mains power supply to prevent any electrical shock or other risks resulting from improper handling.
• Do not wear rings, watches, jewellery, hanging clothes (e.g. ties), torn clothes, scarves, unbuttoned or unzipped jack-
ets, or anyhting that could get caught during the operation of the machine
7 Nm
POWERDUCTION 110LG / 160LG / 220LG
500ms
500ms
500ms
M6
M8
steel
brass
6 Nm
7 Nm
• Rather wear clothing specifically designed for the prevention of accidents, such as:
non-slip shoes, anti-noise helmets, protective goggles, safety shoes, etc ...
• Never use petrol or flammable solvents to clean the product. Prefer the use of wa-
ter and, if necessary, non toxic commercial solvents.
• After maintenance, always put and secure the metal covers back on, before switch-
ing the machine on.
• The ferrite on inducer can be replaced if damaged.
Gas
1/4
M10
clamp
Gas
3/8
brass
7 Nm
2,5 Nm
4 Nm
Inductor
M28
M32
16/22
copper
copper
copper
by hand,
7 Nm max
7 Nm max
4 Nm max
EN
33

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Powerduction 160lgPowerduction 220lg

Tabla de contenido