Load Ramping And Shedding - Tripp-Lite SNMPWEBCARD Guia Del Usuario

Ocultar thumbs Ver también para SNMPWEBCARD:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

5. Load Ramping and Shedding

Click the "Settings" menu button and the "Device" submenu button
to display the Settings > Device page. If your device supports load
ramping and shedding, the "Ramping" tab and/or "Shedding" tab
(Figure 5-1) will be available.
The "Ramping" and "Shedding" tabs each contain a table of the
load segments available for your device. Each load segment has
a "Description" field, an "Action" field and a "Delay" field. The
"Description" field allows you to enter a note about the equipment
connected to the load segment. The "Action" field allows you to
configure the load ramping or shedding behavior by choosing from
the possible actions listed in the drop-down menu. The "Delay" field
allows you to enter the delay (in seconds) before the specified action is
performed. After entering the desired values, click the "Save Changes"
button to make the values active. Ramping sequences are applied when
AC input power is switched on. Shedding sequences are applied when
AC input power is lost, increasing the battery backup runtime available
for supported equipment. You can disable load shedding by setting all
actions to "Remain On." You can disable load ramping by setting all
actions to "Remain Off."
Load ramping and load shedding require a Tripp Lite UPS system or
PDU with switchable load banks (banks of one or more outlets that
can be switched on and off remotely, independent of other outlets).
A device that has switchable load banks can be classified as an
autonomous device or a non-autonomous device, which determines its
load ramping and load shedding characteristics (Figure 5-2).
Autonomous Device
Non-Autonomous Device
An autonomous device can execute stored load shedding and load
ramping configurations independent of an SNMPWEBCARD
or PowerAlert. Configuration of an autonomous UPS system
requires PowerAlert or an SNMPWEBCARD (disconnect the
SNMPWEBCARD network cable before attempting to use an
autonomous UPS system's RS-232 serial port). Configuration of an
autonomous PDU requires an SNMPWEBCARD (the card is pre-
installed in "NET" models). Figure 5-3 lists autonomous devices that
are currently available.
Non-autonomous devices require an SNMPWEBCARD for
configuration and execution of a custom load shedding sequence. Non-
autonomous devices do not support custom load ramping. UPS systems
that have switchable load banks are non-autonomous devices unless
they are listed in Figure 5-3.
Note: Load ramping and shedding can also be configured through
the telnet console. (Select the first menu option "1- Devices" from the
Main Menu, then select the first device from the Device List menu, then
select the third menu option "3- Settings". From the Settings menu,
select the second menu option "1- Device". From the Device Settings
menu, select the second menu option "2- Shedding" for shedding
configuration or the third menu option "3- Ramping" for ramping
configuration.)
Custom Load Ramping
Configuration
Requires SNMPWEBCARD
or PowerAlert.
Not supported.
Figure 5-2: Autonomous and Non-Autonomous Device Characteristics
Figure 5-1: Settings > Device > Shedding & Ramping Tabs
Execution
Functions without
Requires SNMPWEBCARD
SNMPWEBCARD or
PowerAlert.
Not supported.
Requires SNMPWEBCARD.
Part Number
SMART1500CRMXL
SM2200RMDVTAA
SM2200RMXL2UP
SM2200RMXL2UTAA
SMART2200CRMXL
SMART2200RM2U
SMART2200RMXL2U
SMART2600RM2U
SM3000RMNAFTA
SM3000RMXL2UTAA
SMART3000CRMXL
SMART3000RM2U
SMART3000RMOD2U
SMART3000RMXL2U
SMX2200RT2UTAA
SMX2200XLRT2U
SMX3000RT2UTAA
SMX3000XLRT2U
SU3000RTXL2U
SUINT3000RTXL2U
Switched PDU models
Switched PDU models
17
Custom Load Shedding
Configuration
SNMPWEBCARD or
or PowerAlert.
Requires SNMPWEBCARD.
Series Number
All
All
All
All
All
AGSM7501
AGSM6803, AGSM7109
AGSM6907
AGSM7090
All
All
AGSM6908, AGSM6909
All
All
All
AGSM7145
All
AGSM7144
All
All
All with "NET" suffix
All with "PDU3VS" prefix
Figure 5-3: Autonomous Devices
Execution
Functions without
PowerAlert.

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido