REYNAERS CP 50 Manual Del Usuario página 44

Ventanas y balconeras correderas
Tabla de contenido

Publicidad

CP 50
opening of minimum 8 mm diameter, or elongated openings of minimum 5 mm by 15 mm. For the
outer frame the minimum surface is 150 mm² per opening, either 3 round openings of minimum 8 mm
diameter, or an elongated opening of minimum 8 mm by 34 mm.
- On the side at the top of the sliding panel at least 1 opening of minimum 5 mm should always be
drilled. Its function is to guarantee the pressure equalization around the glazing.
- Always drain at the lowest point of the glass rebate.
Remark: For specific drainage we refer to page 37.f.073-075.
1.2.4 Gaskets
All gaskets are of EPDM resistant to weathering and ageing. They should be carefully applied since
the tight sealing of the sliding element depends on their correct application.
a. Applying the glazing gaskets/gaskets
Steps:
1. Correct cutting: the glazing gasket should be cut with special gasket shears (art.no. 090.0121.00)
and can be cut straight or mitred according to the kind of profile connection. Extra overhanging (about
10 mm per metre) is required.
2. Application of the gasket: the gaskets are applied around the glazing; they should be cut slightly
longer than is necessary to compensate for any shrinkage that may occur. Difficulties in applying the
gasket can be solved by the use of silicone spray (art.nr. 086.9551.--).
b. Applying the brushes
Steps:
1. Correct cutting: the brush should be cut with special gasket shears (art.nr. 090.0121.00) and can be
cut straight or mitred according to the kind of profile connection.
2. Application of the brush: the brushes are applied in the appropriate grooves within the profiles.
Difficulties in applying the brush can be solved by the use of silicone spray (art.nr. 086.9551.--).
3. Glueing: In function of the type of profile connection (straight), the brush should be glued at the
ends with contact glue (Reynaglue art.nr. 084.9105.--). This glueing is necessary to avoid the slipping
away of the brush.
c. Applying a closer at the bottom and the top of the meeting section
To obtain a good watertigthness and windtightness, an extra closer should be fitted at bottom and top
of the meeting section:
- art.nr. 062.7114.04
The closer at the top is difficult to fit after the sliding panels have been fitted.
II.2
FITTING
II.2.1
Fitting in the structural work
The fixing to the structural work is done either directly through the profiles by means of for instance
screws and plugs, or by means of fixing lugs.
- The fixings may not be applied less than 40 mm of the wall of the structural work.
- The anchoring may in no way influence the bearing power of the adjacent building parts.
03/2003
Información general sistema
Généralités séries
General information systems
Allgemeine Information Systeme
PRESCRIPCIONES DE TRATAMIENTO
RECOMMANDATIONS DE TRAITEMENT
PROCESSING DATA
VERARBEITUNGSVORSCHRIFTEN
37.B.058

Publicidad

Tabla de contenido
loading

Tabla de contenido