Bulb Seal
Wall Jamb
Strike Jamb
8. Install the Door
CAUTION: Risk of injury or product damage. Unframed tempered glass should not contact hard
surfaces or it may shatter. Do not touch the edge of the tempered glass panel with tools or any hard
objects. Do not set the unframed tempered glass directly on the floor.
Slide the hinge jamb into the other wall jamb. Each slot in the hinge jamb will slide over the screw
body and fit between the clamp and wall jamb.
Tighten the four flathead screws, using the 3/32" hex wrench, until snug.
9. Adjust and Secure the Door
The glass on the door should be aligned evenly with the back edge of the bulb seal. The edge of the
glass should be 3/16" (5 mm) from the strike jamb.
1036565-2-B
Adjust the top edge of
the door glass to be
even with the top edge
of the bulb seal.
Wall Jamb
Strike Jamb Latch
Glass
Bulb Seal
3/16"
(5 mm)
Glass
Top View
Hinge Jamb
10
Hinge Jamb
Flathead
Wall Jamb
Screw
Clamp
Wall Jamb