TECHNICAL DATA
TYPE
Thermal power – output
Fuel
Electrical supply
Motor
Capacitor
Ignition transformer
Pump
Absorbed electrical power
■
Burner with CE marking in conformity with EEC Directives: Machine Directive 2006/42/EC, Low Voltage
Directive 2006/95/EC, Electromagnetic Compatibility 2004/108/EC and Efficiency 92/42/EEC.
■
The burner meets protection level of IP 40, EN 60529.
1 – Return line
2 – Suction line
3 – Gauge connection
4 – Pump pressure regulator
5 – Vacuum gauge connection
6 – Hydraulic jack with air-damper
7 – Combustion head adjustment screw
8 – Reset button with lock-out lamp
9 – Flange with insulating gasket
10 – Start delaying device
2406
482 T58
95 – 240 kW
-
Light oil, viscosity 4 – 6 mm
Single phase,
220 V
Run current 2.2 A – 3250 rpm – 340 rad/s
4 µF
Secondary 8 kV – 16 mA
Pressure 8 – 15 bar
0.41 kW
Fig. 1
D8077
BURNER EQUIPMENT
Quantity
2
1
4
1
1
1
1
GB
8 – 20 kg/h
2
/s at 20 °C
~
±
10%
60Hz
Description
Flexible pipes with nipples
Flange with insulating gasket
Screws and nuts for flange
Maintenance assembly
Cable grommet
Screw with two nuts for flange
ENGLISH