4.3 MENU B (key P2) - List of parameters
The following table lists the entries of menu A and reports a short description of the parameters that can be adjusted.
Refer to paragraphs dedicated to each feature for more information
MENU B
Manual Motion
End position
Ped. Position
High Speed OP
Low Speed OP
High Speed CL
Low Speed CL
High speed
Torque Opening
Low speed
Torque Opening
High speed
Torque Closure
Low Speed
Torque Closure
4.4 MENU C (key P3) - List of parameters
The following table lists the entries of menu A and reports a short description of the parameters that can be adjusted.
Refer to paragraphs dedicated to each feature for more information
MENU C
Language
Backlight
Allows to move the door at low speed by using the keys located on the control board.
This feature is fundamental in order to check the motion during the installation
Learning the full run of the door, both in opening and in closing
WARNING: this operation must start when the door is completely closed
Learning of the pedestrian opening run
WARNING: this operation must start when the door is completely closed
Regulation of the speed of the door during the opening phase
NNN: speed expressed in Hz (frequency of the wave supplied to the motor). (100 Hz - By factory for SUPER 3000 FAST and JOLLY FAST)
Regulation of the door speed during the opening phase when approaching the end of the run
NNN: speed expressed in Hz (frequency of the wave supplied to the motor). (50 Hz - By factory for SUPER 3000 FAST and JOLLY FAST)
Regulation of the door speed during the closing phase
NNN: speed expressed in Hz (frequency of the wave supplied to the motor). (100 Hz - By factory for SUPER 3000 FAST and JOLLY FAST)
Regulation of the door speed during the closing phase when approaching the end of the run
NNN: speed expressed in Hz (frequency of the wave supplied to the motor). (50 Hz - By factory for SUPER 3000 FAST and JOLLY FAST)
Torque supplied to the motor during the opening phase
NNN: percentage of torque supplied to the motor. (80 % - By factory for SUPER 3000 FAST and JOLLY FAST)
Torque supplied to the motor during the opening phase when approaching the end of the run
NNN: percentage of torque supplied to the motor. (80 % - By factory for SUPER 3000 FAST and JOLLY FAST)
Torque supplied to the motor during the closing phase
NNN: percentage of torque supplied to the motor. (80 % - By factory for SUPER 3000 FAST and JOLLY FAST)
Torque supplied to the motor during the closing phase when approaching the end of the run
NNN: percentage of torque supplied to the motor. (80 % - By factory for SUPER 3000 FAST and JOLLY FAST)
EXIT
Select the language
Backlighting of the display
OFF: the light of the display is disabled
ON: the light of the display is enabled and its automatic switching-off is timed (Energy saving). (By factory for SUPER 3000 FAST and JOLLY FAST)
Total reset of factory settings of the control board.
RESET
WARNING: all programming operations and the setting of the control board must be repeated after this operation
EXIT
41
G
B

Publicidad

Tabla de contenido
loading

Tabla de contenido