RONDO'/ESTELLE 4-5 ErP BE
KEY
L
Line
N
Neutral
IG Main switch
TS Safety stat
TC Boiler stat
SA Green voltage LED
P
C.H. pump
B
Permanent Feeding Burner SIME (optional)
PERMANENT FEEDING
BRUCIATORE CON
BURNER
ALIMENTAZIONE PERMANENTE
RONDO'/ESTELLE 6-7 ErP BE
B1 Permanent Feeding Burner (not supplied)
B2 Direct Feeding Burner (not supplied)
TA Room stat
OP Programmer's clock (optional)
NO T E: When a room stat is to be fitted remove the link
between terminal 4 and 5 on the connector plug.
To connect the programmer's clock (OP), remove the link
between terminals 5 and 8.
D.H.W. STORAGE TANK
COLLEGAMENTO BOLLITORE ACS
TB
PB
C
2
PI
L N
1
2
3
4
5
6
NC
NA
R
C
KEY
L
Line
N
Neutral
IG Main switch
TS Safety stat
TC Boiler stat
SA Green voltage LED
P
C.H. pump
B1 Permanent Feeding
Burner (not supplied)
OP Programmer's
clock (optional)
PB D.H.W. pump
1
TB D.H.W. stat
R
Relais
NOTE: To connect the ambient
thermostat (TA), remove the
link between terminals 1-5 of
the boiler unit terminal block.
Remove links 4-5 and 8-9
from the boiler terminal
block.
To connect the programmer's
clock (OP), remove the link
between terminals 5-8.
Fig. 6
Fig. 6/a
49