Electrical Connection - Sime RONDO'/ESTELLE 8 Instrucciones De Instalación Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

brackets (1-2) depending on the mo-
del.
– fix the sides to the upper brackets (5
- 1) with the four self-tapping screws
supplied;
– fit the two back panels (6) and (7) of the
sides with the ten self-tapping screws
supplied;
– fit the control panel (9) inserting the
two lower tangs of the panel on the
drains on the sides, and fix it with the
four self-tapping screws supplied. Be-
fore carrying out this operation unwind
the capillaries of the two thermostats
and the thermometer and place the
respective feelers in the sheath (10),
fixing all with a capillary pin;
– fit the front panel (8) fixing it to the si-
des with pin clutches;
– complete the assembly by fixing the lid
2
48
(12) to the sides with pin clutches.
NOTE: Remove the "Testing Certificate"
from inside the combustion chamber
and keep together with the instructions
manual.
2.6
ELECTRICAL CONNECTION
(fig. 6)
The boiler is fitted with an electricity
cable, and requires a 1ph - 230V - 50Hz
power supply through the main switch
protected by fuses.
The room thermostat (required for
enhanced room temperature control)
should be installed as shown in fig. 6.
Connect the burner with the cable sup-
plied.
6
7
11
9
3
NO T E: Device must be connected to an
efficient earthing system. SI M E de c li n es
all responsibility for injury caused to
persons due to failure to earth the boi-
ler. Always turn off the power supply
before doing any work on the electrical
panel.
2.6.1
To connect the boiler to the boiler unit
proceed with the following operations:
– remove the casing lid of the boiler and
the back protection of the control pa-
nel in order to have access to the ter-
minal board of the boiler;
– connect the cables as shown in the
diagram (fig. 6/a).
12
5
1
1
Electrical connection
to the boiler unit (fig. 6/a)
4
9
8
Fig. 5