Combustion Chamber; Compatible Burners - Sime RONDO'/ESTELLE 8 Instrucciones De Instalación Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

1.6
COMBUSTION CHAMBER
The combustion chamber is of the
straight flow type and complies with
standard EN 303-3 appendix E.
The dimensions are shown in fig. 3.
L
mm
Rondò/Estelle 4 ErP BE
405
Rondò/Estelle 5 ErP BE
505
Rondò/Estelle 6 ErP BE
605
Rondò/Estelle 7 ErP BE
705
1.7
COMPATIBLE BURNERS
(
EN 267)
In general, the oil burner that is compati-
ble with the boiler should use spray
of the semi solid type.
Section 1.7.1 shows the matching table
of the burners together with the boilers
have been tested with.
1.7.1
"SIME" burners
Code Nozzle
Rondò/Estelle 4 ErP BE
8099155
Rondò/Estelle 5 ErP BE
8099156
Rondò/Estelle 6 ErP BE
8099157
Rondò/Estelle 7 ErP Be
8099158
(*) Values obtained during operation
1.7.2 Burners assembly (fig. 4)
The boiler door details is shown in figure
4 for burner mounting.
The burners must be regulated such that
the CO
value is that indicated in point
2
1.3, with a tolerance of ± 5%.
Volumen
3
dm
24,0
30,5
37,0
43,5
Type
ø
FLUIDICS
0,60
FLUIDICS
0,75
FLUIDICS
1,00
FLUIDICS
1,25
270
Atomising
Pump pressure
angle
80°HF
80°HF
80°HF
80°HF
L
Adsorbed power
bar
consumption (*)
W
13
201
12,5
190
12
263
11,2
260
Fig. 3
Fig. 4
45

Publicidad

Tabla de contenido
loading

Tabla de contenido