Check position of the guard:
The rubber extraction ring should protrude over
the sanding pad by approx. 0–1 mm.
If required, correct (see "Adjusting the guard").
Insert the mains plug into the socket.
Switch on the electric power tool (without
locking the button) and leave it running for
approx. 30 seconds. Check for imbalances
and vibrations.
Switch off the electric power tool.
Adjusting the guard
klqb
qÜÉ=êìÄÄÉê=Éñíê~Åíáçå=êáåÖ=ëÜçìäÇ=éêçíêìÇÉ=
çîÉê íÜÉ=ë~åÇáåÖ=é~Ç=Äó=~ééêçñK=MÓN=ããK=
qç ÅçãéÉåë~íÉ=Ñçê=ïÉ~ê=çå=íÜÉ=Çá~ãçåÇ=
ë~åÇáåÖ=é~ÇI=íÜÉ=ÜÉáÖÜí=çÑ=íÜÉ=Öì~êÇ=Å~å=
ÄÉ ~ÇàìëíÉÇK
Loosen the screw connection on the guard.
Set the guard hood to the required height.
Tighten the screw connection.
20
Switching the electric power tool
on and off
Brief operation without engaged
switch rocker:
1. Press and hold down the starting lockout.
2. Press the switch.
3. To switch off, release the switch.
Continuous operation with engaged
switch rocker:
1. Press and hold down the starting lockout.
2. Press and hold down the switch.
3. Press the locking button.
LD 24-6 180