BEFORE YOU BEGIN
Read these instructions completely and
carefully.
IMPORTANT
instructions for local inspector's use.
IMPORTANT
governing codes and ordinances.
• Note to Installer – Be sure to leave these
instructions with the Consumer.
• Note to Consumer – Keep these instructions
for future reference.
• Skill level – Installation of this vent hood
requires basic mechanical and electrical skills.
• Completion time – Approximately 4 to 6 hours
• Proper installation is the responsibility of the
installer.
• Product failure due to improper installation is
not covered under the Warranty.
CAUTION
Due to the weight and size
of these vent hoods and to reduce the risk
of personal injury or damage to the product,
TWO PEOPLE ARE REQUIRED FOR PROPER
INSTALLATION.
FOR YOUR SAFETY
WARNING
Before beginning the
installation, switch power off at service panel
and lock the service disconnecting means
to prevent power from being switched on
accidentally. When the service disconnecting
means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the
service panel.
8
— Save these
— Observe all
Island Chimney
Vent Hood

PRODUCT DIMENSIONS

*Height to
ceiling
27-5/8"
* For supplied duct cover ceiling height for vented installation and
recirculating installation, refer to the table on page 12.

INSTALLATION CLEARANCES

24" Required Min.
36" Recommended Max.
36" Typical
maximum above the cooking surface. The hood
installation height above the cooking surface
depends upon ceiling height and duct cover
limitations. The telescopic duct cover conceals the
ductwork running from the top of the hood to the
ceiling.
NOTE: Installation height should be measured from
the cooking surface to the lowest part of the hood.
This hood must be installed onto a wall. It can be
vented to the outdoors, or it can be installed for
recirculating operation. Recirculating Kit included
with hood.
13-1/8"
*Height to Ceiling
Vented Recirculating
Min
34 5/8"
34 5/8"
Max
51 3/4"
57 1/4"
2-3/8"
35-7/8"
These vent hoods are
designed to be installed
onto a wall with no
above cabinets.
• Install these hoods
between the required
24" minimum and
36" recommended
maximum above the
cooking surface.
The vent hood must be
installed between the
required 24" minimum
and 36" recommended
49-2000833 Rev. 0
3-1/8"

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido