Notes On The Documentation; Original Instructions For Use; Observing Other Applicable Documents; Storing Documents - Vaillant allSTOR plus VPS 800/4-5 Instrucciones De Instalación Y Mantenimiento

Ocultar thumbs Ver también para allSTOR plus VPS 800/4-5:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 31
2

Notes on the documentation

2.1

Original instructions for use

These instructions are the original instructions for use within
the context of the machine directive.
2.2

Observing other applicable documents

Always observe all the operating and installation instruc-
tions included with the system components.
2.3

Storing documents

Pass these instructions and all other applicable docu-
ments on to the end user.
2.4

Validity of the instructions

These instructions apply only to:
Product article number
VPS 800/4-5
0010039300
VPS 1000/4-5
0010039301
VPS 1500/4-5
0010039302
VPS 2000/4-5
0010039303
3

Product description

The product is a buffer cylinder.
3.1

Product design

1
Opening for purging
valve
2
Heating water flow for
domestic hot water
station
3
Boiler flow for domestic
hot water demand
4
Boiler flow for domestic
hot water demand
20
1
2
3
4
5
6
7
8
9
10
11
5
Boiler return for do-
mestic hot water de-
mand
6
Boiler flow for heating
water demand/heating
circuit flow
7
Boiler flow for heating
water demand/heating
circuit flow
8
Boiler return for heating
water demand
9
Boiler return for do-
mestic hot water de-
mand/heating circuit re-
turn
3.2

Positions of the sensor straps

1
2
3
4
5
6
7
8
1–8
Sensor straps 1–8
3.3
Product description
The product intermediately stores the heating water from one
or more heat generators in a heating system. A domestic hot
water station for generating domestic hot water can also be
connected.
3.4

Data plate

The data plate is located on the front of the product. A
second data plate is enclosed with the product and must be
affixed to the heat insulation before the unit is handed over
to the end user. (→ Page 24)
The data plate contains the following information:
Information
Serial no.
VPS .../4-5
Vs
Pmax
Tmax
21073700201168840908005011N8
Installation and maintenance instructions allSTOR plus 0020314387_00
10
Boiler return for heating
water demand/heating
circuit return
11
Heating water return
for domestic hot water
station
Meaning
Serial number
Product designation/product
generation – equipment vari-
ant
Fill quantity
Maximum permissible operat-
ing pressure
Maximum permissible operat-
ing temperature
Barcode and serial number
7th to 16th digit = product
article number

Publicidad

Tabla de contenido
loading

Tabla de contenido