Appendix; A Troubleshooting; Technical Data; Connection Dimensions - Vaillant allSTOR plus VPS 800/4-5 Instrucciones De Instalación Y Mantenimiento

Ocultar thumbs Ver también para allSTOR plus VPS 800/4-5:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 31

Appendix

A
Troubleshooting
Symptom
Heating water drips out of the
product.
Splashing noises can be heard
from the product.
The control displays an incor-
rect cylinder temperature.
B

Technical data

B.1

Connection dimensions

Di-
Unit
Toler-
men-
ance
sion
± 10
A
mm
± 10
B
mm
± 10
C
mm
± 10
D
mm
± 10
E
mm
± 10
F
mm
± 10
G
mm
± 10
H
mm
± 2
I
mm
0020314387_00 allSTOR plus Installation and maintenance instructions
Possible cause
Leaking connections
Air in the product
Temperature sensor defective
Temperature sensor is posi-
tioned incorrectly
I
VPS 800/4-5
VPS 1000/4-5
1832
2212
1670
2051
1330
1598
1020
1220
820
1020
636
822
421
451
231
231
790 diameter
790 diameter
Measure
Seal the connections.
Purge the product.
Replace the temperature sensor.
Check that the temperature sensors are positioned correctly
(→ Basic hydraulic diagrams).
D
E
F
G
H
VPS 1500/4-5
VPS 2000/4-5
2190
2313
1973
2080
1573
1656
1227
1201
1000
1008
797
803
521
551
291
298
1000 diameter
1100 diameter
A
B
C
27

Publicidad

Tabla de contenido
loading

Tabla de contenido