Appendix
A
Troubleshooting
Symptom
Heating water drips out of the
product.
Splashing noises can be heard
from the product.
The control displays an incor-
rect cylinder temperature.
B
Technical data
B.1
Connection dimensions
Di-
Unit
Toler-
men-
ance
sion
± 10
A
mm
± 10
B
mm
± 10
C
mm
± 10
D
mm
± 10
E
mm
± 10
F
mm
± 10
G
mm
± 10
H
mm
± 2
I
mm
0020314387_00 allSTOR plus Installation and maintenance instructions
Possible cause
Leaking connections
Air in the product
Temperature sensor defective
Temperature sensor is posi-
tioned incorrectly
I
VPS 800/4-5
VPS 1000/4-5
1832
2212
1670
2051
1330
1598
1020
1220
820
1020
636
822
421
451
231
231
790 diameter
790 diameter
Measure
▶
Seal the connections.
▶
Purge the product.
▶
Replace the temperature sensor.
▶
Check that the temperature sensors are positioned correctly
(→ Basic hydraulic diagrams).
D
E
F
G
H
VPS 1500/4-5
VPS 2000/4-5
2190
2313
1973
2080
1573
1656
1227
1201
1000
1008
797
803
521
551
291
298
1000 diameter
1100 diameter
A
B
C
27