Helo Piccolo DEL Instrucciones Rapidas página 15

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
Sauna heater stones
- Sauna stones should be piled sparsely in order to enhance ventilation between the stones. Do not bend the heating
elements together or against the frame
- Stones are piled so that they cover the heating elements. Do not, however, pile a large heap of stones on the heating ele
ments.For a sufficient amount of stones refer to page 3. Any small stones in the package of stones must not be piled on the
sauna heater.
- Empty the stone compartment regularly, at least once a year in private use, remove small and broken stones and replace
them with new ones.
- In commercial use this operation must be performed at least every second month.
- Structural clay tiles are not allowed. They may cause damage to the sauna heater that will not be covered by the warranty.
- Do not use soapstone as sauna rocks. Any damages resulting from this will not be covered by the stove warranty.
- Do not use lava stone as sauna rocks. Any damages resulting from this will not be covered by the stove warranty.
DO NOT USE THE HEATER WITHOUT STONES.
LocatRemote controlling
The Heater can be remotely controlled by connecting a closed
contactor, which can be pulse triggered, to connectors 3 and 4
of a RJ10 circuit board. The recommended cable size is AWG 24
or 26. The maximum length of an AWG 24 cable is 200 m when
using a Trend controller.
The maximum length of an AWG 26 cable is 130 m when using
a Trend controller.
NOTE: Incorrect connections may break a circuit board.
Additional sensor (NTC)
Pin 1
Pin 2
NTC 10
kOhm
Pin 3
NTC 10
kOhm
Pin 4
Sensor (Sec/NTC)
Pin 1
End stop
Pin 2
NTC 10
kOhm
Pin 3
NTC 10
kOhm
Pin 4
End stop
Table 2 Coupling order of RJ connectors to
circuit board
Principle image when 1601 - 31 (RA - 31 Trend) is used as control panel
Heater
Adapter circuit
board OLEA 99
Door switch
The door switch refers to the switch on the sauna door. This switch complies with regulations. Public and private saunas must
have a door switch, i.e. saunas where the heater can be switched on from outside the sauna, e.g. using an On/Off button or a
similar method.
For additional information about door switch. www.tylohelo.com
Remote control switch (Ext switch)
Pin 1
3.3 V
Pin 2
CPU
Pin 3
Pin 4
GND
3.3 V
CPU
10V
Figure 4 . Order of RJ 10 connectors. Sensor, Door switch, Remote control,
Sensor cable
silicone 4 x 0,25 mm²
Heater
Adapter circuit
1= Blue
board OLEA 99
2= White
3= Red
4= Yellow
RJ 10 intermediate cable
Pin layout of a RJ10 circuit board connector
Circuit board RJ connectors
To switch
GND
To switch
12 VDC
Control panel RJ 10
connectors
Additional NTC
4
3
2
1
OLET 31
Pin layout of a RJ10
connector
Door switch
Pin 1
Pin 2
Alarm LED
Pin 3
Door switch
Pin 4
Door switch
Limiter
Control panel
1601 - 31
GND
GND
12 VDC
4