Descargar Imprimir esta página

Beninca DA.24SL Libro De Instrucciones página 14

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Keep the power cables away from the control cables. To avoid interference use two separate sheaths
(see EN 60204-1 15.1.3).
1)
Connect the push-buttons and the devices following the diagrams.
2)
All the inputs N.C. (normally closed) must be linked to the clamp n
used.
3)
All the inputs N.O. (normally open) must not be linked if they are not used.
4)
If several couples of photo-devices are installed, contacts must be put into series.
5)
The clamps A and B (2nd radio channel), C (2nd blinker) and D, E (electro-lock) can be installed on
request.
For the connections to these clamps see the diagram "Links".
6)
Important!
In order to obtain a correct working of the accessories linked to the central unit (especially photo-
devices) it is very important that the whole system (motor + central unit) has only one ground refer-
ence.
It is then necessary to connect the motor frame with the clamp "-" (negative) of the battery by
means of a cable on the central unit (see figure).
If a good ground is available it is better to connect the whole system with it.
Central unit board
Motor
frame
Motor
7)
Place all the trimmers of the central unit board at mid-course and exclude the automating closing
for the while by closing the correspondent dip-fix on the board; if the electro-lock has been in-
stalled too, select the right power tension on the basis.
8)
Place the automation at mid-course manually and check that the springs tension balance the weight
of the barrier perfectly.
9)
Connect the line 230Vac and the eventual two hermetical leaden batteries 12Vcc, 3Ah, connected
into series, to the correspondent clamps, paying attention to the polarity: in the case the batteries
are linked, you should also insert the battery charger board in order to make them work.
10) Now the leds "F.Apert.", "F.Clos.", "Photo" and "Stop" should light on the basis and the leds
"P.Apert.", "P.Closing" and "S.Bys" must remain obscured.
If this does not happen, check that the correspondent links are correct.
11) By moving the barrier manually, check that the led "F.Apert." turns off a little before the complete
aperture and that the led "F.Clos." turns off a little before the complete closing because of the
intervention respectively of the aperture brake and the closing brake.
12) Place the barrier at mid-course again and disconnect the device of manual triggering.
14
24Vcc
Battery
Motor
230Vac
- +
+
-
M
-
+
2 batteries 12Vcc
°
3 (common) in case they are not
Motor in d.c.
Fixing screws
To the negative of battery
+
-
Batteries
Example of a connection
motor frame
Linking cable

Publicidad

loading