Troubleshooting Chart - STA-RITE DC13318V Manual Del Usuario

Bombas sumergibles para sumideros
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Troubleshooting

Troubleshooting Chart

Risk of electrical shock. Unplug the pump before touching it or servicing it.
Symptom
Probable Cause(s)
Pump is not plugged in.
Blown fuse or tripped breaker.
Low line voltage.
Pump won't start
or run.
Defective motor.
Defective float switch.
Clogged or jammed Impeller.
Backflow of water from piping.
Pump starts and
stops too often.
Defective float switch.
Defective float switch.
Restricted discharge (obstacle or
Pump won't
ice in the piping).
shut off.
Restricted intake screen.
Low line voltage.
Debris caught in the impeller.
Worn or defective parts or
Pump operates
plugged impeller.
but delivers little
or no water.
Check valve installed without
vent hole
Restricted intake screen.
Check valve is installed either
backward or upside down.
Corrective Action
Make sure the pump is plugged into a proper outlet.
Determine and fix the cause of the failure. Replace the fuse with a
fuse of proper size or reset breaker.
Check the size of the wiring on the circuit feeding the pump and
from the main switch on the property. If everything is OK, contact
your power company or hydro authority.
Replace the pump.
Replace the float switch.
If the impeller won't turn, unplug the pump, remove the lower
pump body, and locate the source of the binding. Replace the
impeller if necessary.
Install or replace the check valve.
Replace the float switch.
Replace the float switch.
Unplug the pump, remove it from the sump, and clean the pump
and piping.
Unplug the pump, remove it from the sump, and clean the intake
screen and impeller.
If the voltage is below 110 volts, check the size of the wiring
from the main switch on the property. If OK, contact your power
company or hydro authority.
Remove the pump and clean out the impeller.
Clean the impeller if it's plugged; replace the impeller if
necessary; otherwise replace the pump.
Drill a 1/8" (3mm) dia. hole 1" to 2" above the pump discharge
and below the waterline.
Remove the pump and clean out the intake screen.
Be sure the check valve is installed correctly (the flow arrow
should point away from the pump).
6

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Dc15018t

Tabla de contenido