4. Using the contactor cases

The contactor case 2005 – 40 (WE – 40), can be used with the following sauna heaters:
The models of the control panels that can be used to control contactor cases WE 40. Pure or Elite.
Refer to the control panel operating manual for more specific instructions.
The contactor box is intended to be installed outside the sauna
installation. A connection box must be installed in the sauna room with a semi-fixed installation on the sauna
heater.

5. Locating the connecting box for the connection cable in the sauna room

A = Specified minimum safety clearance, see table 1, 2 or 3
1. Recommended location for the connecting box
2. Silumin box recommended in this area.
3. This area should be avoided. Always use a silumin box.
In other areas, use a heat-resisting box (T 125 °C) and heat-resisting cables (T 170 °C). The
connection box must be clear of obstacles. When installing the connection box to zones 2 or 3,
refer to the instructions and regulations of the local energy supplier.
1105 – XX
- SKLE
1105 – XX
- SKLE
1105 – XX
- Laava
1105 – XX
- Laava
1106 – XX
- Octa
1712 – XX – 04
- Cup / Vienna
1712 – XX – 04
- Cup / Vienna
1714 – XX – 04
- Havanna
1714 – XX – 04
- Havanna
A
Figure 1. Location for the connection box
9 kW 230V 3~
9 – 15 kW 400V – 415V 3N~
9 kW 230V 3~
9 – 15 kW 400V – 415V 3N~
9 – 15 kW 400V – 415V 3N~
4,5 – 8 kW 400V – 415V 3N~
4,5 – 8 kW 230V 3~
4,5 – 9 kW 400V – 415V 3N~
4,5 – 9 kW 230V 3~