Hilti PS 1000 Manual De Instrucciones página 16

Ocultar thumbs Ver también para PS 1000:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 36
6.
The "Color scheme", "Contrast" and "Param." buttons can be used to change the visualization and calculation
parameters.
NOTE The "Param." values must be set before a scan is made (please refer to the operating instructions displayed
by the tool).
7.
The 4-way controller can be used to set the depth/thickness according to the position of the object.
8.
End the scan by pressing the start/stop button.
A double beep indicates that the scan has ended.
5.4 Quickscan recording
NOTE
This feature is not available with the PS 1000‑B.
It can be used to scan a long path on a concrete structure. After ending the scan, objects that lie perpendicular to the
scanning direction can be made visible in a plan view or cross-sectional view.
1.
Select the "Quickscan recording" function from the main menu.
2.
Set the scanning direction.
3.
Hold the scanner against the surface of the area to be scanned.
4.
Start the scan by pressing the start/stop button.
A beep indicates the start of the scan and a red recording mark appears in the display. A minimum length of
32 cm must be scanned in order to obtain data suitable for evaluation. The red bar showing scanning progress
turns black when the minimum length is reached. The maximum length of scan is 10 m.
5.
Move the scanner in the direction you have previously set.
Audible and visual warnings are emitted if the scanner is moved at a speed approaching the maximum permitted
scanning speed. If the scanner is moved too quickly, the scan will be canceled and the data not saved.
Do not change the scanning direction. If the scanner is moved more than 16 cm in the opposite direction, the
scan will be canceled automatically.
6.
End the scan by pressing the start/stop button.
A double beep indicates that the scan has ended.
7.
Use the "Preview last scan" function to check the last scan. Use the function button at top left to select the
function to be controlled by the 4-way controller. The 4-way controller can be used to set the depth/thickness
according to the position of the object.
NOTE The "Contrast", "Param." and "Visualization" buttons can be used to change the visualization and
calculation parameters. If you change the parameters under "Param.", the data must be recalculated. To do this,
press the "OK" button.
5.5 Imagescan 4
The Imagescan function creates an image of the objects present in an area of a concrete structure. The objects are
shown in a plan view and a cross-sectional view.
1.
First use Quickscan detection in order to determine how the objects are oriented (see Section 5.3).
2.
Place the reference grid on the surface to be scanned at right angles to the direction in which the objects are
oriented and secure it with the adhesive tape.
NOTE The distances indicated by the scanner display and by the reference grid will correspond only when the
reference grid remains flat and taught and is securely attached to the surface.
3.
Select "Imagescan" from the main menu.
4.
Select the grid size (possible only with the PS 1000) and the starting point.
5.
Hold the scanner against the surface of the area to be examined, at the starting point and in line with the grid.
Printed: 22.12.2017 | Doc-Nr: PUB / 5310430 / 000 / 02
en
13

Publicidad

Tabla de contenido
loading

Tabla de contenido