geberit Sigma 80 Manual Del Usuario página 13

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 40
All manuals and user guides at all-guides.com
Settings
With the Geberit WC flush control with Sigma80 actuator plate, specific settings can be made. The instructions can be
found on the following pages.
Overview
Setting
Description
A Activate or deactivate
The actuator plate and WC can be cleaned without triggering a flush.
the cleaning function
The cleaning function can be activated and then deactivated following
completion of the cleaning process. The cleaning function is
automatically deactivated after 3 min.
B Select the colour of
The following colours can be selected:
the sensor lights
Blue, turquoise, magenta, orange, yellow
C Set the sensor
Three different settings are possible.
illumination
D Activate or deactivate
When the automatic flush actuation is activated, the WC flush control
automatic flush
always activates a long flush when you step back after use. Manual
actuation
actuation is not necessary.
Setting 1 = deactivated
Setting 2 = activated
E Reset to factory
Settings B, C and D are reset to the factory setting
setting
With the Geberit WC flush control with Sigma80 actuator plate, further settings are possible. If you want to change any
of the settings in the following table, please consult a skilled person.
Skilled persons will find information on the settings at www.geberit.com.
Setting
Description
Interval flush
The WC flush control activates the flush at
regular time intervals.
Flush volume for
The flush volume for a short flush can be set
short flush
so that the optimum volume for the respective
WC ceramic appliance is obtained.
Detection time
The minimum time for detecting a user within
the detection range can be changed (relevant
in the case of automatic flush actuation).
Cleaning time
The time span during which the WC flush
control is inactive in the cleaning function can
be changed.
Sensor illumination
The distance between the user and the
detection distance
actuator plate at which the sensor illumination
is activated can be changed.
1. The sensor illumination always remains off and does not come on
even when you approach the WC
2. The sensor illumination always remains on, even when you step
back from the WC and leave the room
3. The sensor illumination comes on as soon as you approach the WC
and goes off again when you step back
Factory setting
Remarks
Not active
Adjustment range 1–168 h
Level 3
Adjustment range 5 levels
7 s
Adjustment range 1–60 s
3 min
Adjustment range 1–30 min
Level 3
Adjustment range 5 levels
Settings
DE
EN
FR
IT
Factory setting
NL
ES
Blue
PT
Setting 3
DK
NO
SE
FI
Setting 1
IS
PL
HU
SK
CZ
SL
HR
SR
EE
LV
LT
BG
RO
GR
TR
RU
AE
CN
JP
13

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Sigma 80116.092.sg.1116.090.sg.1

Tabla de contenido