SIMPLIFIED INSTRUCTIONS FOR K400 WITH L1 24V-CRX
1° Connecting the accessories
COMMON
A+TEST / A-
24Vdc 0,5A ±15%
PHOTOCELL AUTO-TEST
OR ENERGY SAVING
(LOW BATTERY)
WITH BATTERY
24Vdc 0,5A ±15%
OPERATION
OPEN
CLOSE
SINGLE COMMAND
PEDESTRIAN
TIMER
COMMON
COMMON
STOP
PHOTOCELL 1
PHOTOCELL 2
EDGE 1
EDGE 2
ANTENNA
BRAIDING
RUN TRIMMER - high-speed regulator
For gates weighing from 0 to 200 kg is recommended to set the RUN trimmer from 1/2 to MAX.
For gates weighing from 200 to 400 kg is recommended to set the RUN trimmer from MIN to 1/2.
LOW SP TRIMMER - slow speed approach regulator
Adjustment is performed to determine the correct speed at the end of opening and closing according to the gate or when there is friction that might cause the system to function poorly.
TCA TRIMMER - AUTOMATIC CLOSING pause time regulator for TOTAL or PEDESTRIAN openings
This trimmer makes it possible to adjust the pause time for total or pedestrian automatic closing. Only with gate completely open (total) or partially open (pedestrian) and LED DL11 ON (trimmer
rotated clockwise to activate the feauture).
The pause time (for a totally opened gate) can be adjusted from a minimum of 2 s up to a maximum of 2 minutes.
TRIMMER SENS - impact sensor regulator
With this trimmer it is possible to adjust the impact reaction:
- with trimmer turned fully counter-clockwise and DL15 OFF, impact sensor deactivated.
- with trimmer at minimum, the impact reaction occurs after 3 seconds (low sensitivity)
- with trimmer at halfway, the impact reaction occurs after 1.5 seconds (medium sensitivity)
- with trimmer at max, the impact reaction occurs after 0,4 seconds (high sensitivity)
2° Installing and adjusting the limit switch cams
Position the cams at the ends of the rack rail.
Tighten the two screws to secure them in place.
Open the shutter door of the K400.
Insert the key and turn in a clockwise direction.
Pull the lever to unlock the operating system.
Check the cam intervention point by opening and closing the gate.
N.B.: The cams should press the electric micro-switches before the moving part
touches the mechanical stops (K400 FCE). The DL4 and DL5 LEDs switch off
when the cams are detected by the proximity sensor (K400 FCM).
Position the gate halfway and re-secure the operating system.
ITA
ESP ENG FRA GRE DEU RUS ARA THAI BUL FAR TUR
24 Vdc 3 W
24 Vdc 20 W
LED
ANTENNA
433 MHz
MANUAL RELEASE
L.S. OPEN
SAFETY
AND CLOSE
ENCODER
M
BACKUP BATTERIES
FOR BATTERY CHARGER BOARD (OPTIONAL)
HIN
CHI
POL HUN CEK KOR
POWER SUPPLY
230Vac 50Hz
FUSE
T 1,6A
TRANSFORMER
24Vac
10Vac
K400 FCE
K400 FCM