Collar with
Flange Up
Cast Iron Baths
Mounting Nut
Auxiliary Shower Outlet Port
Bath Outlet Port
8. Install the Transfer Valve
CAUTION: Risk of product damage. Excessive heat will damage
the internal plastic components.
IMPORTANT! Do not apply excessive heat while soldering. Direct
the torch flame away from the brass body.
IMPORTANT! Only apply direct heat to the connectors and
extensions.
IMPORTANT! If there is limited access to the solder connections or
if any other risk of excessive heat being applied to the brass body
exists, remove the cartridge prior to soldering. If you remove the
cartridge, protect the seals and O-rings from becoming dirty, being
damaged, or misaligned.
IMPORTANT! If the transfer valve is to be used in a two-way
configuration, solder a cap to the auxiliary outlet.
Solder the inlet and outlet connectors and extensions.
Remove the plaster guard and plated nut from the valve. Do not
remove the cartridge.
Remove the collar from the brass body.
Thread the mounting nut down onto the brass body.
Slide the washer onto the brass body until it is flush against the
mounting nut.
Kohler Co.
Plaster Guard
Cartridge
Plated Nut
Brass Body
Collar with Flange Down
Washer
Handshower Outlet Port
Cap
1/2" Male Adapter
Mixed Water Inlet Supply Port
Other Baths
13