Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

293 Wright Street • Delavan, WI 53115
1-800-937-6664 • www.omnifilter.com
GENERAL INSTRUCTIONS
The system and installation must comply with all state and local laws
and regulations.
"Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or
after the system." Systems certified for cyst reduction may be used
on disinfected waters that may contain filterable cysts.
Performance Data
Flow Rate: ......................................................... .5 GPM (1.9 LPM)
Min./Max. Operating Pressure ..........25 psi/125 psi (172 - 862 kPa)
Min./Max. Operating Temperature................35°F/100°F (2°C/38°C)
Replacement Cartridge ...........................................................CB20
Capacity..................................................750 Gallons (2,839 Liters)
NOTICES
Install this filter on a cold water line only. Do not use on water
lines exceeding 100° F (38°C). Water pressure minimum is 25 psi
(172 kPa) and the maximum is 125 psi (862 kPa).
Protect unit from direct sunlight and freezing temperatures.
Do not use pipe dope or similar compounds. They can ruin plas-
tic. Use Teflon
TM
tape to seal pipe thread joints.
Keep unit clean with soap and water. Do not use spray cleaners
or insecticides near unit.
Intended for indoor, non-commercial use only.
For extended periods of non-use turn the water off and remove
the filter cartridge. Place the cartridge in a plastic bag, seal, and
refrigerate.
Safety glasses must be worn during installation.
Tubing and hose dimensions are based on outside diameters
(OD). For water line sizes other than those listed, consult a
plumber or hardware store.
Before using the water, flush the new filter for 30 minutes.
Run drinking or cooking water for 5-7 seconds prior to collecting
the water for use.
Change cartridge if changes in taste, color or flow of water
occur.
This filter is not a water purifier and is not intended for use with
contaminated water.
Comply with all state and local laws regarding the installation of
water treatment devices.
Use only OMNI filter CB20 cartridges with this housing, or the
warranty is void.
When to change the filter cartridge
Cartridge should be changed every 6 months or after 750 gallons of
water used. Which ever occurs first.
INSTALLATION INSTRUCTIONS
Choose a Location; See Figure 1.
1. Position the filter housing bracket on the wall of the cabinet
nearest the cold water line beneath the sink. Leave a 3" mini-
mum clearance between the bottom of the filter housing and
the floor of the cabinet. Mark the bracket slots on the wall.
2. Drill a 1/8" hole at each of the two marks, install the drywall
screw anchors (available locally) and insert the mounting screws.
Leave each screw 1/4" out from the wall.
TM
E.I. DuPont de Nemours, and Company, Corporation, Wilmington, Delaware.
©2002, Omnifilter
Undersink Water Filter
®
Figure 1
Install the Omni faucet; See Figure 2.
3. A. For stainless steel sinks you can drill a 7/8" diameter hole in a
convenient location or use the existing sprayer hole. Before
drilling make a small indentation with a punch, in the location
where you will be installing the faucet.
B. For porcelain sinks, place a piece of masking tape over the
faucet location, then score position with a punch before drilling.
NOTE: A special drill is required for porcelain sinks.
4. Remove the hardware from the faucet stem. Slide the large rub-
ber washer onto the threaded stem and insert the faucet into
the sink hole.
5. Slide the large metal washer and the thumb nut onto the faucet
stem. Hand tighten the thumb nut against the underside of the
sink to secure the faucet in place.
Figure 2
Printed in U.S.A.
System - CBF20
INSTALLATION INSTRUCTIONS
Drywall
Screw
Anchors
LED
Mounting
Screws
Threaded Stem
of Faucet
Large Rubber
Washer
Existing Sink
Faucet Sprayer Hole
Large Metal
Washer
Thumb Nut
OM564 (Rev. 10/4/02)

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Omnifilter CBF20

  • Página 1 Undersink Water Filter ® System - CBF20 293 Wright Street • Delavan, WI 53115 1-800-937-6664 • www.omnifilter.com INSTALLATION INSTRUCTIONS GENERAL INSTRUCTIONS The system and installation must comply with all state and local laws Drywall and regulations. Screw Anchors “Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.”...
  • Página 2 Connect the 1/4” (smaller diameter) blue tubing to the faucet stem; See Figure 3. "OUT" Port 6. Firmly push the 1/4” blue poly tubing all the way into the faucet 3/8" x 1/4" Slip Fit stem until firmly seated. Tube Fitting "IN"...
  • Página 3 Faucet Base Figure 10 For further operating, installation, or maintenance assistance: Call Omnifilter Customer Service at 800-937-6664 Tested and certified by NSF International against ANSI/NSF Standard 42 for the reduction of Chlorine, Class I and ANSI/NSF Standard 53 for Mercury, Cysts,...
  • Página 4: Repair Parts List

    REPAIR PARTS LIST Part Description Qty. CBF20 Faucet Spout FG100025 Faucet, Outer Sleeve FG100026 Faucet Monitor Replacement Battery 21301 Stop Valve Adapter Tee FG100018 3/8” White Poly Tubing 15110 Bracket Screws 11920 Filter Cartridge, CB20 CB20 Sump O-Ring 19125 Sump Portion of Filter Housing 13206 1/4”...
  • Página 5: Instructions Générales

    Système de filtration d’eau sous l’évier – CBF20 INSTRUCTIONS D’INSTALLATION INSTRUCTIONS GÉNÉRALES Le système et l’installation doivent se conformer à tous les règlements et lois Chevilles pour vis Drywall de la province et de la municipalité. Screw de cloisons sèches Anchors «...
  • Página 6: Filter Cartridge

    Branchement du tube bleu de 1/4 de pouce de "OUT" Port Orifice « OUT » diamètre (le plus petit diamètre) sur la tige du robinet; se reporter à la Figure 3. Raccord de tube à 3/8" x 1/4" Slip Fit Pousser fermement et à...
  • Página 7 Remplacement de la pile du robinet; se reporter à la Figure 10. Déposer le bec du robinet de sa base : tout en tenant la base du robinet d’une main et la base du bec de l’autre main, tirer fermement sur le robinet.
  • Página 8: Liste Des Pièces De Rechange

    LISTE DES PIÈCES DE RECHANGE Réf. Désignation Qté CBF20 Bec du robinet FG100025 Manchon extérieur du robinet FG100026 Pile de rechange du module du robinet 21301 Té de l’adaptateur du robinet d’arrêt FG100018 Tube en poly blanc de 3/8 de po...
  • Página 9: Sistema De Filtración De Agua Para Debajo Del Fregadero - Cbf20

    Sistema de filtración de agua para debajo del fregadero – CBF20 INSTRUCCIONES PARA LA INSTALACIÓN INSTRUCCIONES GENERALES El sistema y la instalación deben cumplir con todas las leyes y las reglas Anclas de tornillo Drywall estatales y locales. Screw para pirca Anchors "No lo use con agua que pueda ser peligrosa desde el punto de vista...
  • Página 10 Conecte el tubo azul de 1/4" (diámetro más pequeño) al caño del grifo; consulte la Figura 3. Empuje firmemente el tubo de polietileno azul de 1/4" hasta el final del Abertura "OUT" "OUT" Port caño del grifo, hasta que quede bien asentado. Accesorio deslizante de 3/8"...
  • Página 11 Faucet Base Figura 10 Para mayor información sobre la operación, instalación o el mantenimiento: Llame al Servicio al Cliente de Omnifilter: 800-937-6664 Comprobado y certificado por NSF International con respecto a la Norma 42 de ANSI/NSF para la reducción de cloro, Clase I y a la Norma 53 de ANSI/NSF para la reducción de mercurio, espora, plomo, COV, amianto,...
  • Página 12: Lista De Repuestos Para Reparaciones

    LISTA DE REPUESTOS PARA REPARACIONES Clave Descripción de la pieza Cant. CBF20 Pico del grifo FG100025 Manguito exterior del grifo FG100026 Pila de repuesto del monitor del grifo 21301 Tubo en T del adaptador de la válvula de tope FG100018 Tubería de polietileno blanco de 3/8"...

Tabla de contenido