Wiring of CAN communication wire
The ISS 1Play requires a two-wire CAN BUS (for CAN H and CAN L). The two-wire are
connected to the J8 connector of the inverter, as the following figure:
2.2.1
Connection of the BYD B-BOX Premium HVS/HVM to the inverter
There are two ways to do it:
•
Two wires: connecting the two wires to the pin 1 and pin 2, as seen in the following
table. It can be appreciated that the pin 1 is connected with the BMS CAN_H of the
inverter and the pin 2 with the BMS CAN_L of the inverter.
•
Ethernet wire: connecting the RJ45 in the CAN terminal of the battery. Then, connecting
the two wires to the inverter, as shown in the following figure:
ABH2010IMC19_
Use and settings of the INGECON SUN STORAGE 1Play TL M working with BYD B-BOX
Premium HVS/HVM
ISS 1Play TL M
BMS CAN H
BMS CAN L
BYD HVS/HVM
Pin 1 CAN_H
Pin 2 CAN_L