4

Basic principles of addressing

Electronics (left)
Inputs
1
2
1
4−input module
2
8−input module
3
4−output module
4
4−output module
1. Counting with valves from the node to the right.
(lower valve address = pilot valve coil 14;
higher valve address = pilot valve coil 12).
2. Counting with electrical outputs from the node to the
left and from top to bottom.
3. Counting with electrical inputs from the node to the
left and from top to bottom. Please observe the status
bits.
You will find detailed information on addressing your valve
terminal in the Electronics manual".
Festo VIFB6−..− 0208a English
Node
Outputs
3
4
Pneumatics (right)
Outputs
5
6
5
Single sub−base
6
Double sub−base
7
Round up
6
6
7
17