11
TECHNICAL DATA
11
Technical data
Polarization
Sensing range (with reflector
PL80A)
Sensing range max. (with
reflector PL80A)
Light spot diameter/distance
Supply voltage V
S
Output current I
max.
Max. switching frequency
Max. response time
Enclosure rating
Protection class
Circuit protection
Ambient operating temperature –40 °C ... +55 °C
Limit value; operation in short-circuit protection mains max. 8 A; residual ripple max. 5 V
1)
2)
With light / dark ratio 1:1
3)
Signal transit time with resistive load
4)
A = U
-connections reverse polarity protected
V
B = inputs and output reverse-polarity protected
D = outputs overcurrent and short-circuit protected
11.1
Dimensional drawings
Table 5: Dimensional drawings
13.6
(0.54)
M18x1
1
2
Figure 5: ZLx18-1xxxxx / ZLx18-Axxxxx, cable
12
ZLD18-xxxxx2
ZLD18-xxxxx8
✓
✓
6.8 m
4.2 m
7.8 m
5.0 m
11 mm / 500 mm
63 x 55 mm / 500
mm
DC 10 ... 30 V
DC 10 ... 30 V
1)
≤ 100 mA
≤ 100 mA
500 Hz
500 Hz
2)
1 ms
1 ms
3)
IP67
IP67
III
III
A, B, D
A, B, D
4)
–40 °C ... +55 °C
2 x Ø 3.5 (0.14)
3
4
14.1
(0.56)
23
(0.91)
ZLE18-xxxxx2
-
7.9 m
9.0 m
11 mm / 500 mm
DC 10 ... 30 V
1)
≤ 100 mA
500 Hz
2)
2)
1 ms
3)
3)
IP67
III
A, B, D
4)
4)
–40 °C ... +55 °C
ss
13.6
(0.54)
1
2
Figure 6: ZLx18-2xxxxx / ZLx18-Bxxxxx, cable
ZLE18-xxxxx8
-
5.0 m
6.2 m
63 x 55 mm / 500
mm
DC 10 ... 30 V
1)
1)
≤ 100 mA
500 Hz
2)
1 ms
3)
IP67
III
A, B, D
4)
–40 °C ... +55 °C
2 x Ø 3.5 (0.14)
M18x1
3
14.1
4
(0.56)
21.9
(0.86)
8021946 | SICK
Subject to change without notice