Technical Data; Technical Specifications; Dimensional Drawings - SICK WTB4-3P2100S79 Monitoring Manual De Instrucciones

Ocultar thumbs Ver también para WTB4-3P2100S79 Monitoring:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 23
11

TECHNICAL DATA

11
Technical data
11.1

Technical specifications

Recommended sensing range for the best performance
Sensing range max.
Light spot size / distance
Supply voltage U
B
Ripple
Output current I
max.
Current consumption
Switching frequency
Max. response time
Enclosure rating
Protection class
Circuit protection
en
Ambient temperature, operation
1)
Object with 90% remission (based on standard white DIN 5033)
2)
Limit values
Reverse polarity protected U
Residual ripple max. 5 V
3)
With light / dark ratio 1:1
4)
Signal transit time with resistive load
5)
Reference voltage DC 50 V
6)
A = U
-connections reverse polarity protected
B
C = Interference suppression
D = outputs overcurrent and short-circuit protected
11.2

Dimensional drawings

20
O P E R A T I N G I N S T R U C T I O N S | WTB4-3P2100S79 Monitoring
connections
B
ss
Preferred direction of the target object
1
Center of optical axis, sender
2
Center of optical axis, receiver
3
Yellow LED: status of received light beam
4
Green LED: supply voltage active
5
WTB4-3P2100S79
30 ... 150 mm
30 ... 150 mm
1)
7 mm / 50 mm
DC 10 ... 30 V
2)
100 mA
2 Hz
3)
250 ms
4)
IP67
III
5)
A, C, D
6)
-40 ... +60 °C
8027117.1COU/2022-02-14 | SICK
Subject to change without notice

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido