9
Disassembly and disposal
10
Maintenance
11
Technical data
11.1
Technical specifications
The "Technical Data" chapter contains only an extract of the technical data of the sensor.
The complete technical data can be found on the homepage
Features
Sensing range
Min. sensing range
Sensing range max.
Recommended sensing range for the best performance
1)
Object with 90% remission (based on standard white DIN 5033)
2)
on black with 6% remission
8027085/2022-05-31 | SICK
Subject to change without notice
LED/fault pattern
Object is in the path of the
beam, yellow LED does not
light up
The sensor must be disposed of in line with applicable country-specific regulations.
When disposing of them, you should try to recycle them (especially the precious met‐
als).
NOTE
Disposal of batteries, electric and electronic devices
•
According to international directives, batteries, accumulators and electrical or
electronic devices must not be disposed of in general waste.
•
The owner is obliged by law to return this devices at the end of their life to the
respective public collection points.
•
WEEE:
This symbol on the product, its package or in this document,
indicates that a product is subject to these regulations.
This SICK sensor is maintenance-free.
We do, however, recommend that the following activities are undertaken regularly:
•
Clean the optical interfaces using a plastic cleaner, do not use acetone or methy‐
lated spirits.
•
Check the fittings and plug connectors
No modifications may be made to devices.
Subject to change without notice. Specified product properties and technical data are
not written guarantees.
OPERATING INSTRUCTIONS
Cause
Remission capability of the
object is insufficient
www.sick.com
under the part number of the sensor.
RSB
2 mm
300 mm
1)
2 mm ... 45 mm on black 6%
O P E R A T I N G I N S T R U C T I O N S | RSB - Roller Sensor Bar
Measures
Move object closer to sensor.
2)
37