ALARM PRIORITY SET

This sets the priority of the 8 ALARM inputs so ALARM can work corresponding to the priority.
The priority of the DEFAULT is ALARM1, ALARM2, ALARM3, ALARM4, ALARM5, ALARM6,
ALARM7, ALARM8. If the ALARM is working at the same time and the priority is the same, it
will operate according to the DEFAULT priority. While the ALARM is working, it cannot detect
MOTION.

ALARM IN SET

This sets the input TYPE to [NO] (Normal Open), [NC] (Normal Close), or [OFF] depending on
the features of the SENSOR connected.

ALARM OUT SET

Each ALARM input corresponds to one of the 3 ALARM OUT.

AUTO SET

This menu designates what to do at the time of ALARM input. Once an alarm is given, the
camera will shortly move to the PRESET position corresponding to the respective alarm as
follows. PRESET1 to ALARM1~8 PRESET9 to MOTION.
After DWELL TIME at a PRESET position, PATTERN or SCAN will be in action according to the
AUTO SET setup.
Setup of OFF/1/2/3/HALF1/HALF2/FULL/SCAN1~4 is available.
OFF dues not perform PATTERN or SCAN after moved to PRESET and each menu has its own
function as follows.
PATTERN 1~3 : Preset PATTERN action
HALF1 : Continuous operation of PATTERN1 + PATTERN2
HALF2 : Continuous operation of PATTERN2 + PATTERN3
FULL : Continuous operation of all the above
SCAN 1~4 : Scanning as set

AUX OUT CONTROL

This sets the ALARM OUT motion to continue or act only when the ALARM is working. If it is set
to OFF the ALARM OUT motion will operate only when the ALARM is working. (Active "Low"),
and if it's set to ON, the ALARM OUT will always operate regardless of the ALARM.